FIT-3.0/FIT-4.0 Filter Integrity Tester

FIT Serials Integrity Tester are designed for testing integrity of filters and filter systems . The test meet to verify the sterilizing filter in the FDA, the State Pharmacopoeia and GMP specification requirements.

SKU: FIT-3.0/FIT-4.0 Category:

FIT Serials Integrity Tester are designed for testing integrity of filters and filter systems . The test meet to verify the sterilizing filter in the FDA, the State Pharmacopoeia and GMP specification requirements. The FIT-4.0 Integrity Tester is compact, handy to use, and fully automated integrity test instrument, which performs bubble point, diffusion flow, enhanced bubble point, and water-based test for hydrophobic filters. The first domestic launch of integrity test for water-based test for hydrophobic filters to meet different customer needs.

Main features:

  • The scientific electronic signature and classification to distinguish the responsibility easily, and to prevent false operation.
  • Display of test data and curves in real time, monitoring the whole process of testing.
  • Provides automatic printing set function, the user can operate more simple and convenient.
  • Water Based test (WH) for Hydrophobic Filter: using purified water as test liquid instead of IPA and Ethanol, thus it can avoid trace quantity of ethanol or IPA contamination when testing filters.
  • The instrument can store 500 history record and curve.
  • Advanced “water intrusion method” has solved the disadvantage that the hydrophobic filter can only be tested immersed in organic solvent .
  • Advanced automatic control system, no need of manual adjusting pressure, to ensure the accuracy and precision.
  • Real-time displaying test data and curve, monitoring the whole testing process.
  • Dual-core operation, with PC software.
  • Covers all of the functions of foreign similar instruments.
  • More perfect user extension management, users can change the password according to need.
  • Add the automatic protection function for tested filters, to avoid doing harm to the filter because of overvoltage testing.
  • Provide automatic printing setting, and make the operation more easy and convenient.
  • 5.7 ” backlight digital LCD, display clearly.
  • Testing the Diffusion flux of the disc membrane is of important significance for judging the characteristics of the membrane.

Specifications:

Model

FIT-4.0

FIT-3.0

power

170-240VAC,50/60Hz, 110W

170-240VAC,50/60Hz, 110W

Maximum working pressure

8000mbar

8000mbar

Minimum working pressure

100mbar

100mbar

Dimensions (L*D*H)mm

240X380X285

400X380X235

Test pressure

500-6900 mbar

500-6900 mbar

Test accuracy

Upstream volume test: ± 4%;
bubble point: ± 50 mbar;
diffusion flow: ± 4%;
water immersion: ± 0.1 ml/min

Upstream volume test: ± 4%;
bubble point: ± 50 mbar;
diffusion flow: ± 4%;

Working condition

Temperature: 5℃±35℃;
Moisture: 10~80%

Temperature: 5℃±35℃;
Moisture: 10~80%

Test time

Upstream volume test : 5min±2min;
Quick D test: 10min±2min
Base BP test: 15min±2min
Enhanced test: 20min±2min
water immersion: +5min±2min

Upstream volume test : 5min±2min;
Quick D test: 10min±2min
Base BP test: 15min±2min
Enhanced test: 20min±2min

Checklist print

Input parameters & output data and result

Input parameters & output data and result

History record

500 test records + graphic curves

500 test records + graphic curves

LCD

5.7″ ; TFT, monocular

5.7″ ; TFT, monocular

Series I/O type

RS232

RS232

Language of menu

English

English

Enquiry Form

    Your Name:

    Your Email:

    Company Name (Organization):

    Message:

    This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

    Scroll to Top