DSC4000 new advanced DSC differential scanning calorimeter. The instrument has been completely redesigned and upgraded from appearance to software, making it more portable. At the same time, the sensor adopts anti-interference and corrosion-resistant treatment to extend its service life. At the same time, the instrument has high sensitivity and improved measurement accuracy. At the same time, the software is more intelligent and easy to operate.



Test range OF DSC differential scanning calorimeter
DSC4000 series DSC differential scanning calorimeter can be used to test glass transition temperature, phase transition temperature, melting point, thermal enthalpy, curing temperature, product stability and oxidation induction period.
Comply with test standards
- General rules for differential scanning calorimetry (DSC) of plastics
- Plastics Differential Scanning Calorimetry (DSC) Part 2: Determination of Glass Transition Temperature
- Plastics Differential Scanning Calorimetry (DSC) Part 3: Determination of Melting and Crystallization Temperature and Enthalpy
- Plastics Differential Scanning Calorimetry (DSC) Part 4_Determination of Specific Heat
Performance Advantages OF DSC differential scanning calorimeter
- Brand-new furnace structure, better baseline and higher precision. Heating adopts indirect conduction method, with high uniformity and stability, reducing pulse radiation, which is better than traditional heating mode.
- Wide temperature range, able to meet the test temperature requirements of different materials.
- Fast cooling. The instrument adopts a variety of cooling methods, including air cooling, semiconductor, mechanical refrigeration and liquid nitrogen refrigeration, which can achieve fast cooling and improve the efficiency of the experiment.
- Automatically switch between two atmosphere flows, with fast switching speed and short stabilization time. At the same time, add one more protective gas input.
- The supporting analysis software has been upgraded, with more comprehensive analysis data and more intelligent and convenient operation.
- The instrument has high sensitivity, which greatly improves the accuracy of experimental tests.
- Customized services can be provided to meet different testing needs.
Technical Parameters OF DSC differential scanning calorimeter
| Model | DSC4000 | DSC4000C | DSC4000D | DSC4000L |
| Temp. range | RT ~ 600°C | -50~600°C | -70~600°C | -170~600°C |
| DSC Range | ±1000mW | ±1000mW | ±1000mW | ±1000mW |
| Temperature sensitivity | 0.001 | 0.001 | 0.001 | 0.001 |
| Heating rate | 0.1~100°C/min | 0.1~100°C/min | 0.1~100°C/min | 0.1~100°C/min |
| Cooling speed | -0.1~20°C/min | -0.1~40°C/min | -0.1~60°C/min | -0.1~80°C/min |
| Temperature control method | Intelligent PID temperature control, intelligent memory temperature control mode, temperature accuracy combines the advantages of dynamic and static algorithms, with self-tuning and self-optimization functions | Intelligent PID temperature control, intelligent memory temperature control mode, temperature accuracy combines the advantages of dynamic and static algorithms, with self-tuning and self-optimization functions | Intelligent PID temperature control, intelligent memory temperature control mode, temperature accuracy combines the advantages of dynamic and static algorithms, with self-tuning and self-optimization functions | Intelligent PID temperature control, intelligent memory temperature control mode, temperature accuracy combines the advantages of dynamic and static algorithms, with self-tuning and self-optimization functions |
| Resolution | 0.01uW | 0.01uW | 0.01uW | 0.01uW |
| Gas flow | 0~200mL/min | 0~200mL/min | 0~200mL/min | 0~200mL/min |
| Timing frequency | 1~20Hz adjustable | 1~20Hz adjustable | 1~20Hz adjustable | 1~20Hz adjustable |
| DSC Noise | 0.1μW | 0.1μW | 0.1μW | 0.1μW |
| Temperature resolution | 0.0001°C | 0.0001°C | U.000T°C | 0.0001°C |
| Cooling method | Air Cooling | Semiconductor Refrigeration | Mechanical Refrigeration | Liquid nitrogen |