DSC1000A Upgraded differential scanning calorimeter

DSC1000A is a differential indicator with the highest precision. The sensor adopts imported material E couple with high sensitivity. The signal acquisition circuit is shielded and protected, with strong anti-interference and high baseline stability.

SKU: DSC1000A Category: Tag:

DSC1000A Upgraded differential scanning calorimeter DSC analyzer is a differential indicator with the highest precision. The sensor adopts imported material E couple with high sensitivity. The signal acquisition circuit is shielded and protected, with strong anti-interference and high baseline stability.

The differential scanning calorimeter is a touch screen type, which can perform glass transition temperature test, phase transition test, melting and enthalpy test, product stability, curing, and oxidation induction period test.

YouTube player

Technical Features

  • Industrial-grade 7-inch touch screen, rich in display information.
  • Brand-new metal furnace body structure, with better baseline and higher accuracy. The heating adopts indirect conduction method, which has high uniformity and stability, reduces pulse radiation, and is better than traditional heating mode.
  • The USB communication interface has strong versatility, reliable and uninterrupted communication, and supports self-recovery connection function.
  • Automatically switch the two-channel atmosphere flow, with fast switching speed and short stabilization time. At the same time, a protective gas input is added.
  • The software is simple and easy to operate.

Technical Parameter

Model DSC1000A (upgrade model of DSC1000)
Temperature range  room temperature~550°C air cooling
Temperature resolution  0.01°C
Temperature fluctuation  ±0.01°C
Temperature repeatability  ±0.1°C
Heating rate  0.1~80°C/min
Data scan  heating scan
Temperature control method  heating, constant temperature, cooling (auto program control)
DSC range  0~±600mW
DSC resolution  0.01uW
DSC sensitivity  0.001mW
Power supply  AC220V/50Hz or customized
Atmosphere control gas  nitrogen, oxygen (automatic switching of the instrument)
Gas flow  0-300mL/min
Gas pressure  0.2MPa
Display mode  24bit color, 7-inch LCD touch screen display
Data interface  standard USB interface
Parameter standard  equipped with standard materials (indium, tin), users can calibrate the temperature by themselves