CBC-600 Automatic Oxygen Bomb Calorimeter

The CBC-600 automatic calorimeter has the characteristics of high degree of automation, simple structure and exquisite appearance.

SKU: CBC-600 Category:

Application field

The CBC-600 automatic calorimeter has the characteristics of high degree of automation, simple structure and exquisite appearance. The calorimeter contains an internal cylinder water automatic charging and discharging system, and adopts an advanced internal cylinder water measurement method without adding electrolyte to distilled water; the circulating water volume of the system is up to 40 liters, ensuring continuous measurement of more than 20 samples. The system temperature is stable; using CBC-700-11 molding die, the appearance is comparable to similar international products such as IKA and Parr.

 

This product can be used in electric power, coal, metallurgy, petrochemical, environmental protection, building materials, papermaking, geological prospecting, scientific research institutions and other industries to measure the calorific value of combustibles such as coal, coke, petroleum and cement black raw materials. It is especially suitable for coal mines and power plants. , New dry process cement plants and other units conduct conventional coal calorific value detection.

 


Technical characteristics

1. Long-term stability technology of heat capacity

2. Automatic filling and drainage technology

3. No water temperature adjustment technology

4. Low calorific value accurate measurement technology

5. Rapid determination technology

6. Cotton thread ignition technology

7. Accurate prediction technology of H content

8. Fast ash determination technology

 

Technical parameter

Model CBC-600
Heat capacity precision ≤0.15%
Long-term stability ≤0.20%
Maximum absolute error of calorific value For coal ≤120KJ/kg, for coal gangue ≤60 KJ/kg
Heat test time The main period of routine measurement is 8 minutes (12-19 minutes in the whole process), and the main period of coal rapid measurement is 4 minutes (7 minutes in the whole process)
Temperature resolution 0.0001℃
Test Range 0-32MJ/KG
Environmental requirements Temperature 2-39℃, relative humidity<80%
Power requirements 220V±20V, 50Hz±1Hz
Instrument power consumption <80W
Ash content rapid determination program (Optional) The ash test time is 5 minutes, the absolute error of the ash parallel sample is ≤0.5%
Host size (length × width × height) (mm) 450×500×390