TDM Series High Temperature Dilatometer, Determination of linear thermal expansion

TDM Series High Temperature Dilatometer is used to measure temperature in the state of metal materials, ceramics, masks, fire-proof material and other non-metallic materials in the process of being heated roast expansion and contraction performance, also apply to the ceramic tiles linear thermal expansion tests.

SKU: TDM Series Category:

TDM series(PCY series) High Temperature Dilatometer also called thermal expansion instrument is used to detect the high-temperature expansion properties of solid inorganic  materials and metal materials, especially corundum, refractory materials, shell and core materials for precision casting, ceramics, ceramic raw materials, porcelain clay, glaze, glass, graphite, carbon and other inorganic (organic) materials, metal products, and polymer materials, providing necessary testing means for scientific research and teaching.

TDM thermal expansion instrument is also suitable for the determination of linear thermal expansion of ceramic tiles in accordance with 3810.8-2016, the determination of average linear  thermal expansion coefficient of glass in accordance with 16920-1997, the determination of thermal expansion coefficient (CTE) of graphite electrodes in accordance with 3074.4-2016, and the 7320 “Test Method for Thermal Expansion of Refractory Materials”. It also fully meets the requirements of YBB00282002 [Linear Thermal Expansion Coefficient Test] of pharmaceutical packaging materials  of the State Food and Drug Administration.


Main technical parameters of High Temperature Dilatometer

Model

TDM-1200N

TDM-1400N

TDM-1700N

Maximum furnace temperature

1,200 °C

1400 °C

1700 °C

Measured deformation scope

+5mm

sensitivity

1um

electrical precision

+5 °C

Heating rate

0-100 °C/min computer program temperature control, adjustable.

Computer calculate

Automatically calculate expansivity, the line swelling volume

Automatic calculation of the compensation factor compensation may artificial amendment.

specimen size

(2-15)×(2-15)×(20-50)mm, Square/round is acceptable

Systematic measurement error

±0.1-0.5%

electricity

 220V,2KW

Features

Wisdom expansion device automatically facility, recording, storage, printing several Accordingly, the printing temperature-expansion coefficient curve.

Software

All testing operations are completed computer interface, easy to operate and provide a full range of software easier to learn.

Enquiry Form

    Your Name:

    Your Email:

    Company Name (Organization):

    Message:

    This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.