Penetrometer

PT-D217-2801C

It is mainly used to determine the needle penetration of bituminous mixture and cone penetration of lubricating grease (or petrolatum).It is also suitable to determine solid particle,powder, colloid an draw-food materials such as cheese,glycine,butter,cream and leavening.It can be widely used in food industry,highway engineering and other industrial fields.

More details

Product info

Summary
The instrument is designed and made as per national standard of People’s Republic of China GB/T 4509-2010 Standard Test Method for Penetration of Bitumen, GB/T269 Standard Test Method forCone Penetration of Lubricating Greaseand Petrolatum and T0604-2011 Asphalt Penetration Test in the Industrial Standard of People’s Republic of China JTGE20-2011 Specifications and Test.Methods of Bitumen and Bituminous Mixturefor Highway Engineering as well as ASTM D5 Standard Test Method for Penetration of Bituminous Materials and ASTM D217 Standard Test Methods for Cone Penetration of Lubricating Grease. It is mainly used to determine the needle penetration of bituminous mixture and cone penetration of lubricating grease (or petrolatum).It is also suitable to determine solid particle,powder, colloid an draw-food materials such as cheese,glycine,butter,cream and leavening.It can be widely used in food industry,highway engineering and other industrial fields.

I. Main technical features
1.It adopts digital display to show the penetration number.Easy to observe.
2.Six grade softening control.High timing control accuracy.
3. The needle holder can be adjusted roughly and finely. It is convenient to adjust and exact to aim.
4.Equipped with grease masher and constant temperature bath. The temperature in bath can be controlled automatically.Multipurpose and high cost performance.

II. Main technical specifications
1.Measurement range:(0~600)penetration scale
2.Timing controller: 5s,8s,10s,12s,30 sand 60s,bias within±0.1s
3.Resolution: 0.01mm
4.Penetration accuracy: ±1penetration
5.Heater power: 200W;
6.Temperature control accuracy: 25±0.1℃ (Note:The ambient temperature shall not exceed 20 ℃)
7.Temperature control mode: High accuracy digital temperature controller
8.Constant temperature bath: Hard glass bath
9.Stirring:automatically stirred by a magnetic stirrer
10.Standard needle: 2.5±0.05g
11.Standard cone: 102.5±0.05g
12.Needle holder:It can be adjusted roughly and finely.Convenient toad just and exact to aim the sample.
13. Others: Equipped with a cold light source and a magnifier; Convenient for operation and observation.

III. Optional accessories
Other cones: 1/2scalecone,1/4scalecone