PT-OCA-100
Portable octane analyzer is used for instant octane rating of motor gasoline, corresponding to motor and research methods (RON and MON) as well as for cetane number of diesel fuels. In addition for an inquiries, temperature rating of the analyzed liquid and diesel fuel solidification is provided. The results of measuring are displayed on the LCD.
Availability date:
Parameter | Description | According |
Measurement of octane level. | Research (RON), motor (MON) method. | ASTM D 2699-86, ASTM D 2700-86. |
Measurement of cetane level. | Simultaneously with cetane number the type and temperature of hardening of diesel fuel is defined. | ASTM D 4737-03, ASTM D 613, EN ISO 5165. |
Measurement freezing-point of diesel fuel. | It is defined depending on cetane numbers of diesel fuel. | Facultative parameter. |
Measurement type of diesel fuel. | Type of diesel fuel. (S-summer, W-winter, A-arctic) is defined depending on temperature of hardening. | Facultative parameter. |
Portable octane analyzer is used for instant octane rating of motor gasoline, corresponding to motor and research methods (RON and MON) as well as for cetane number of diesel fuels. In addition for an inquiries, temperature rating of the analyzed liquid and diesel fuel solidification is provided. The results of measuring are displayed on the LCD.
The operational principle of the Octane Meter lies in gasoline octane rating and diesel fuel cetane rating based on the analysis of change of properties of an dielectric permeability and electromagnetic induction.
Octane analyzer has the portable compact design and is used for on-line inspection of motor fuel quality in the field and laboratory conditions. The operating conditions of the Octane analyzer usage: ambient temperature from –10C to +30C, relative humidity 80% at 25 C, atmosphere pressure 84-106kPa. The device gets power from DC elements of type AA (supply voltage 6V).
The delivery package of Octane Meter Shatox SX-100K consists of the following components:
Advantages of Octanemeter SX-100K
Technical characteristics
Parameter description | Value |
Types of controlled fuel | all types of gasoline |
Range of measured octane level | 40-120 |
Range of measured cetane level | 20-100 |
Measurement inaccuracy of octane number | 0,5 |
Measurement inaccuracy of cetane number | 1 |
Data display | digital |
Time of measurement, sec | below 10 |
Consumption current, mA | 30 |
Time of continuous running with one set of batteries, hour | 100 |
Operation temperature range | -100С…+40 0С |
Relative humidity, % | 30…..80 |
Atmosphere pressure, kPascal | 64…..106 |
Dimension, mm: |
|
Weight, gr | 680 |
Mean-time-between-failures, hour | >1000 |