Process principle
Ceramic membrane filtration separation technology is a liquid separation process in the form of “cross-flow filtration”. The raw material liquid flows at a high speed in the membrane tube, and the clarified permeate containing the small molecular component is permeable to the membrane in the direction perpendicular to the pressure, and the turbid concentrate containing the macromolecular component is trapped by the membrane, thereby separating the fluid. Concentration, purification purposes.

Features
- Can withstand high temperatures, suitable for filtration in high temperature processes, chemically stable
- High mechanical strength, wide pH tolerance, acid resistance, alkali resistance, resistance to organic solvents and strong oxidants
- Long service life, low overall equipment cost and high cost performance
- High multiples, reducing water usage and reducing wastewater discharge
- Sterilize the membrane module with high temperature steam, suitable for sterilization filtration
Classification
Main component schematic
ABOUT TAMI TUBULAR CERAMIC MEMBRANE
The tubular ceramic membrane imported from France is made of completely high purity materials. The geometric shape is diverse and meets the needs of users.
Tubular ceramic membranes are used in different separation ranges: microfiltration, ultrafiltration, and fine ultrafiltration.
Standard length specifications of the membrane:
Φ10mm:250/600/1201mm
Φ20mm:1178mm
Φ25mm:580/1178mm
Φ41mm:1020mm
Membrane molecular weight
Fine ultrafiltration | Ultrafiltration | Microfiltration |
1kg/mol | 15kg/mol | 0.14um |
3kg/mol | 50kg/mol | 0.20um |
5kg/mol | 150kg/mol | 0.30um |
8kg/mol | 300kg/mol | 0.45um |
0.80um | ||
1.4um |
Membrane application field
Membrane select
Basic information of Ceramic membrane filtration equipment
- Model: MCS-05
- Process Capacity: 30-60L/H
- Membrane Element: French original imported ceramic membrane
- Contact Material: Material AISI 304, food grade hose
- Material Circulation Tank: Effective volume V=30L
System survey
- Ceramic membrane experiment device (MCS-05) can be applied tomicrofiltration, ultrafiltration and fine ultrafiltration
- The membrane can be selected according to the size of material molecular weight, it canseparate the material of 1.4 μm -1KD
- With advantages of simple and flexible operation and easy cleaning, etc.
Power Unit
- Imported GRUNDFOS pump
- Frequency converting control
- High pressure protection device
Membrane Shell
- PH range: 0-14
- Working pressure: <95℃
- Maximum working pressure: <10bar
- Connection type: High pressure clamp quick disconnection
Ceramic Membrane Element
- French original imported ceramic membrane
- Membranetype: φ25mm: 580/1178mm
- Range of application: Microfiltration, ultrafiltration and fine ultrafiltration
Electrical Control Cabinet
- Temperature, pressure, on-line monitoring of liquid velocity
- Pump frequency conversion controller, real-time display speed and frequency
- Temperature, pressure preset alarm
Material Standard
- Contact material part: Material AISI 304, food grade hose material circulation tank
- Non-contact material part: Material AISI 304, carbon steel + spray paint
- Pipeline: Sanitary seamless stainless steel tube
- Valves: Food grade sanitary direct ball valves, diaphragm valves
Specifications of Ceramic membrane filtration equipment
Model | MCS-05 |
Process Capacity | 30-60L/H |
Working Pressure | 0-9.8bar |
Membrane type | French original imported ceramic membrane |
Membrane element loading capacity | 2 pieces ceramic membrane elements |
Single membrane area | 0.25㎡ |
Membrane element length | 1178mm |
Burst pressure: | >95bars |
Maximum working pressure | 10bars |
Membrane pore size | Intercept precision 1.4μm-1KD |
Valve, flow meter | Health ball valve, rotor flow meter |
Pipeline | Material AISI 304, sanitary polishing inside and outside, heat exchanger with stainless steel pipe |
Material circulation tank | AISI 304, effective volume V=30L |
Size | 75*80*171 cm |