Fiber Optic Spectrometer
SP-OF2000 fiber optic spectrometer using global best Richardson blazed grating, sensitivity up to 20%, stray light reduces 50%. Meanwhile, the use of two shining technology, equipped with UV-sensitive CCD, it expands effective band to 200~1100nm for the first time. And all this was placed in the new design72.5mm focal distance/symmetric/non-cross C-T optical platform. Eventually bring you a decent spectrometer.
Typical application areas:
Reflection / transmission spectrum
Because of diversify sample and complex test conditions; spectrum needs to have a strong system versatility and adaptability.
UV fume analysis Requires a high signal to noise ratio, UV sensitivity and optical resolution, which requires a superior performance spectrometer.
LED sorting
light sources usually have larger radiation intensity, which requires fiber optic spectrometer has a dynamic range of more than 3,000:1.
SP-OF2000 fiber optic spectrometer has the following salient features:
1 Double blazed gratings SP-OF2000 adopts best global Richardson grating, and the use of high-end models used double blazed grating among the whole spectrum at 200 ~ 1100nm models, effectively balance the whole spectrum response;
2 UV sensitized CCD SP-OF2000 fiber optic spectrometer using German technology of CCD ultraviolet sensitizers, UV conversion efficiency is 20% higher than the traditional method, life expectancy doubled;
3 Better than 3000: 1 dynamic range SP-OF2000 fiber optic spectrometer goes through new electronic engineering, with more than 3000: 1 dynamic range, significantly better than the other brands of the same level of the spectrometer;
4 .Two high-speed technology SP-OF2000 fiber optic spectrometer has two patented high-speed technology, including high-speed switching technology and flags bit technologies to meet the needs of high-speed automated detection.
1、, Super portable design, small size, light weight, easy to put the spectrometer into systems |
· 2、Telephoto optical design, balanced spectrum optical resolution and sensitivity performance |
· 3、Full spectrum technology, using linear gradient filter and variable grating, solves the wide spectral balance of efficiency and higher order interference problems, the wide spectral coverage up to 200-1100nm |
· 4、high-speed control technology, can set new integration time in 1ms, savings time for spectrometer control |
· 5、Flag bit technology, at any time to check the spectrometer complete state, at any time to interrupt the re- collection, do not need to wait for long time |
· 6、Bottom calling technology, support system integrated development to facilitate users to more quickly develop spectroscopy applications program |
Key Technology
|
|
|
|
|
|
|
|
||||||||
SP-OF2000-EX |
0.44 |
0.79 |
0.97 |
1.54 |
2.72 |
5.45 |
||||||||
SP-OF2000+RD |
0.39 |
0.66 |
0.78 |
1.21 |
2.30 |
4.73 |
||||||||
SP-OF2000-RD |
0.37 |
0.62 |
0.73 |
1.14 |
2.16 |
4.43 |
||||||||
SP-OF2000 |
0.28 |
0.57 |
0.65 |
0.85 |
1.61 |
3.20 |
||||||||
SP-OF2000 |
0.32 |
0.48 |
0.64 |
0.97 |
1.90 |
3.83 |
||||||||
SP-OF2000+ |
0.27 |
0.46 |
0.54 |
0.84 |
1.63 |
3.28 |
||||||||
SP-OF2000+ |
0.16 |
0.29 |
0.36 |
0.51 |
0.93 |
1.86 |
||||||||
SP-OF2000 |
0.16 |
0.36 |
0.41 |
0.51 |
0.85 |
1.73 |
||||||||
SP-OF2000 |
0.16 |
0.40 |
0.41 |
0.48 |
0.68 |
1.27 |
||||||||
SP-OF2000+ |
0.11 |
0.24 |
0.27 |
0.36 |
0.59 |
1.19 |
||||||||
|
|
|
|
|
±20% |
(nm) |
FWHM |
Notes: (1) “space” represents the detector pixel of wavelength spacing; (*)the value indicates slit width in μm; (2) the resolution value is a theoretical value, the actual deviations will be 20%.
Spectral properties
|
External interface
|
Others
|