PT-D93-8C Automatic PMCC Flash Point Tester

The Tester is designed and made as per GB/T261, ASTM D93 “Test Methods for Flash Point of Petroleum Products (Closed Cup Methods)”. It is used to determine the lowest temperature of a petroleum product sample when the mixture of sample vapor and air around the sample contacts flame and flashes when heated in a closed cup under stipulated condition.

SKU: PT-D93-8C Category:

Purpose
PT-D93-8C Automatic PMCC Flash Point Tester is designed and made as per GB/T261, ASTM D93 “Test Methods for Flash Point of Petroleum Products (Closed Cup Methods)”. It is used to determine the lowest temperature of a petroleum product sample when the mixture of sample vapor and air around the sample contacts flame and flashes when heated in a closed cup under stipulated condition. The lowest temperature is the flash point of the petroleum product sample. The instrument has function of automatic program temperature controlling, automatic barometric pressure modification, and modified value calculation. It can automatically control measurement procedures and test data, and it can also save, analyze and print out test data.

Instrument features:

  • Color LCD large screen display, full English interactive interface, no logo keyboard, Prompt menu guiding type input to the parameters as the pre-value of temperature, the sample label, atmospheric pressure and the date of the test;
  • Simulation trace showing the curve of heating up and test time, with English software prompt modification function with the test date, the test time and other parameters prompts;
  • Automatic correction of the influence of atmospheric pressure on the test and calculate the correction value;
  • Differential detection, system deviation automatic correction;
  • Open the lid, ignition, detection, print data is done automatically, the test arm automatically rise and fall;
  • Electronic ignition, forced air cooling.

Technical parameters:

Model PT-D93-8C
Measuring range Room temperature~300°C
Resolution 0.1°C
Repeatability ≤2°C
Reproducibility ≤±4°C
Measured ignition No
Lift way Automatic tilt
Display mode Color screen
Detection mode Automatic
Data output Print
Ignition mode Electricity, gas
Experimental cup number Single cup
Operating environment 10-50°C
Relative humidity 85%
Power supply voltage AC220V
Power frequency 50Hz±5%
Power rate ≤300W

Enquiry Form