PRE-ASE600
PRE-ASE600 is an automatic device for extracting organic components from a variety of solid or semi-solid samples. Fast solvent extractant is a widely used technology in the market because of its extraction efficiency and sample flux are far better than other traditional extraction methods.
Availability date:
Introduction to the instrument
PRE-ASE600 is an automatic device for extracting organic components from a variety of solid or semi-solid samples. Fast solvent extractant is a widely used technology in the market because of its extraction efficiency and sample flux are far better than other traditional extraction methods.
Application area
Functional configuration
Main technical parameters
MODEL | PRE-ASE600 |
Working channel | 6 channels |
Add fluid flow rate | 100 ml/min |
Flow accuracy | Si 1% |
Upper working pressure limit | 20MPa |
Pressure range | 0.3-20 Mpa independent pressure measurement of each channel |
Pressure accuracy | ± 1% of fuu scale |
Extraction time | 20min |
Extraction pool specification | 34ml optional 11ml, 22ml, etc |
Sample treatment size | 10-30g |
Solvent consumption | 30-150 ml/g |
Collection bottle specifications | 200ml optional 60ml, 120ml, and other different specifications of collection bottles |
Heating temperature | 150℃ |
Temperature control accuracy | ± 1℃ |
Temperature control gradient | 0.1℃ |
Proportional valve channel | 4 channels (four solvents can be used at the same time) |
Nitrogen inlet pressure | 0.5-0.8Mpa |
Hybrid accuracy of proportional valve | ± 2% |
Operating voltage | AC200~240V |
Voltage frequency | 50-60 Hz |
Peak power | about 1.5KW |
Environmental conditions | indoor use |
Effective instrument size (L*W*H) | 870*630*815 (mm) |
Instrument weight | about 120kg |
applied range
It is mainly used to extract organic components in various solid or semi-solid samples, and the instrument meets the following standards:
1. Measurement method of 405 pesticide residues in Gas chromatography-mass spectrometry and liquid chromatography-tandem mass spectrometry
2. Determination of 475 pesticides and related chemicals in Gas chromatography-mass spectrometry
3. Measurement of various ginsenosides in ginseng by liquid chromatography-UV detection method
4. Pesticide residues in tea by gas chromatography / mass spectrometry method
5. Organic analysis sample pretreatment method
6. Extraction and pressurized fluid extraction method of organic matter from solid waste
7. Soil and sediment, organic matter extraction and pressurized fluid extraction method