SIT2000H / H2
Availability date:
Based on SIT2000C type spinning drop interfacial tension instrument, it is developed by the improvement of the classic plug-in injector pipe system, anti-corrosion stainless steel heating system and image acquisition. The main characteristics of this product are high temperature pressure resistance, and acid and alkali resistance, H2-type is mud acid resistance. The operation is easier and more stable. The main application areas are: oil EOR (chemical flooding) indoor study and site monitoring; study of surfactants, detergents, emulsions and foams; research fuel oil, lubricants, paints, inks and coatings; pharmaceutical, paper research products, photographic materials, pesticides and so on.
Feature
1, The instrument improves the quartz glass tube pluggable manner, spring thimble against the sample tube, automatically pop up when removing the sample tube easily broken. When injecting the sample into the test again, easier to clean, more convenient operation. Acid and alkali, especially for mud acid and other substances in the oil sector. When injecting the sample into the test again, easier to clean, more convenient operation. Since the inner sleeve made of stainless steel and stainless steel rotor, expansion coefficient of convergence is conducive to temperature conductivity, the material is not susceptible to corrosion and rust, high concentricity, easier to maintain sample tubes horizontally stable, easy to shake.
2, With electric heating temperature control system, capable of constant temperature experiments. The instrument uses a precise PID temperature control technology, heating assembly with a new corrosion resistant stainless steel design, fast heat conduction and easier to uniformly heat the sample tube not need to meet other temperature control devices.
3, Servo motor control system upgrade, motor control and stability;
Of the German imports of US imports of high-speed motor and encoder control technology, servo control system has a complete motor control system upgrades and better compatibility, speed control up to 14,000 rpm / min, speed control accuracy is ± 5 rev / points, the control points up to 500 points, more accurate, more convenient manipulation.
4, Using the latest precision LED control technology while updating the high-speed acquisition and trigger mode CCD image acquisition under low-speed and high-speed rotation conditions are not flashing screen, the image is sharper edge interface, useful for analyzing oil samples turbid fine features.
5, The master program is Windows interface, easy operation, the image as a standard BMP file that can be stored in print. The program uses the world's leading computing technology interfacial tension measured value, simply press the "test", our software automatically controls the speed camera, save the images to calculate interfacial tension value, showing the measured values, the process without human intervention, so as to effectively avoid the human factors on the measured value. You can record the value of interfacial tension with time, speed, temperature changes and all measured values are stored in the database, and export directly to EXCEL documents to be displayed in real-time graph of the measured values. User-friendly software design, powerful database management manages all test data.
6, Low-noise electric viewfinder mechanism interface button operation, simple and convenient. Three leveling design makes it easy to control droplets in the range of available window.
Configuration list
1 | High temperature pressure chamber |
| 1pcs |
2 | Imports of high-speed motor (14000rad / min) |
| 1pcs |
3 | Pressure system (2Mpa) |
| 1set |
4 | Precision electric temperature control system |
| 1set |
5 | Homing drip system |
| 1set |
6 | 60 Acquisition System |
| 1set |
7 | Needle sets |
| 2pcs |
8 | Long and short needle |
| 4pcs |
9 | Quartz tube |
| 8pcs |
10 | Plug |
| 4pcs |
11 | Application software | software | 1set |
12 | Instructions |
| 1pcs |
13 | Operating Manual Electronic Edition |
| 1pcs |
Technical indicators
Measurement mode: capture spinning drop image, the recording centrifuge tube speed, measuring the image geometry, calculated interfacial tension by the formula | |||
model | SIT2000H | SIT2000H2 | |
| |||
Interfacial tension measurement range | 102-10-6mN/m | 102-10-6mN/m | |
The amplification factor of reading range | 0-6mm accuracy0.001mm | 0-6mm accuracy 0.001mm | |
Microscope zoom range | 0.7-4.5X | 0.7-4.5X | |
CCD camera resolution | Digital: 752 * 480 (360 000 pixels) | Digital: 752 * 480 (360 000 pixels) | |
Video capture system | 60 frames / second high-speed acquisition | 60 frames / second high-speed acquisition | |
Lens Control | X-axis manual control viewfinder fine tuning 0.01mm | X-axis motor control viewfinder fine tuning 0.01mm | |
Motor control range | 1000—14000rev/min | 1000—14000rev/min | |
Motor control accuracy | ± 5 rev / min (RPM) | ± 5 rev / min (RPM) | |
Motor speed control | PID single point of control raster | PID single point of control raster | |
Heating system temperature range | room temperature -150 degrees Celsius | ||
pressure systems | 20atm | ||
Temperature resolution | ±0.01℃ | ±0.01℃ | |
heating method | US Pt thermal resistance heating | US Pt thermal resistance heating | |
Temperature display device | Thermocouple program PID control accuracy of 0.01 | Thermocouple program PID control accuracy of 0.01 | |
The external interface of the constant temperature water bath | optional |
| |
Sample tube for measuring | Inner diameter φ4mm、φ2mm ( no mud acid resistance ,but corrosion resistance) | Inner diameter φ4mm、φ2mm ( mud acid and corrosion resistance) | |
Sample tube fastening method | The outer wall of the plug is matched with the inner wall of the rotating shaft | The outer wall of the plug is matched with the inner wall of the rotating shaft | |
Communication interface | RS232serie port | ||
Software System Index | |||
Calculated based on the interfacial tension | 1, the automatic up and down Richard boundary line, on both sides of the boundary between the calculated distance and automatically calculate the interfacial tension | ||
Calculation mode | Automatic, manual adjustments may be second adjustment and marks recorded | ||
Magnification calibration function | Vertical horizontal magnification calibration (correction factor for a variety of sizes) | ||
Database Management | Historical data are saved and the law with database management, historical data can be found, the second adjustment marks and the recording operation can be exported to EXCEL documents and BMP image | ||
Software control function | Temperature, motor | Temperature, motor, viewfinder X-axis motor | |
Camera mode | Single shooting or interval shooting (for example, every 5 minutes interval timer shooting can be a long record) |