PA-6000LDWA
Availability date:
PA-6000LDWA laser particle size distribution analyzer is a high-end particle size analyzer, which integrates dry and wet testing. The wet dispersion system can test conventional samples and emulsion-type slurries. Materials, powders and readily soluble samples. The instrument has advanced optical design, according to ISO13320 and other standards, uses Labgeni's (unconstrained) free distribution mode to calculate particle size distribution, ensuring that each particle size reaches the highest resolution, and fully detects the subtle differences in details of each particle size. Very high resolution in full scale testing.
PA-6000LDWA works with both liquid and dry dispersing system
—The dry system includes host,auxiliary equipment( including vacuum, waste powder collecting can, air purification tank) and quiet air compressor.
—The wet system includes ultrasonic dispersion, mechanical agitation, circulation etc.
—Just click the mouse to shift between liquid and dry without manually replacing the device in order to secure the accuracy and repeatability.
—Dry method or wet method test, no need to change the device, just select dry method or wet method in the test software menu, and the function conversion can be quickly realized. The instrument adopts a metal shell fully sealed structure, which has good electromagnetic shielding performance, and can achieve environmental protection and no pollution in the test, quickly obtain accurate and reliable particle size distribution results, and have the advantages of repeatability, stability, and high resolution.
Application
Dry powder or emulsion particle size distribution analysis including Ferrite, NdFeB, hard magnetic powder, soft magnetic powder, cement, cobalt powder, electronic materials, pesticides, pigments, pharmaceuticals, ceramics, cosmetics, paint and coating, food, calcium carbonate, talc, kaolin, alumina, rare earth, catalyst, blowing agent, refractory material, graphite, etc.
Advanced Optical System
Excellent dispersion system
Wet Dispersion System
Dry dispersion system
Versatile Analysis Software
Specifications
WET METHOD ANALYSIS PARAMETERS | |
Test principle | Full Scale Mie Scattering Theory for Static Scattered Light |
Measuring range | Wet method 0.01µm~3000µm |
repeatability error | ≤1% (D50 deviation of national standard material) |
accuracy error | ≤1% (D50 deviation of national standard material) |
Injection method | Built-in circulating dispersion system |
testing time | <2 minutes (dispersion test cleaning) |
Sample dispersion cell | Volume 500mL, 304 stainless steel |
Sample detection cell | High-quality optical glass integrated reinforced structure (patented) |
Decentralized way | 60w ultrasonic diffuser |
Wet injection | The sample cell is integrated with the ultrasonic disperser and the stirrer, which avoids the re-agglomeration of the sample after dispersion. It has automatic water inlet, automatic cleaning of the sample cell and circulation pipeline. |
test medium | Tap water, distilled water or ethanol, etc. |
Sample dosage | mg~g/each |
DRY METHOD ANALYSIS PARAMETERS | |
Test principle | Full Scale Mie Scattering Theory for Static Scattered Light |
Measuring range | Dry method 0.01µm~3000µm |
repeatability error | ≤3% (D50 deviation of national standard material) |
accuracy error | ≤3% (D50 deviation of national standard material) |
Injection method | Dry automatic sampling system |
testing time | <5 seconds/time |
dispersion pressure | Pressure 0.1—0.8Mpa, adjustable pressure |
Sample silo | Each filling can be tested more than 3 times |
Decentralized way | High-speed turbulent dispersion system |
dry injection | The spray gun inhales the powder instantaneously, the powder feeding device continuously and automatically sprays, automatically tests, and automatically cleans the working chamber. Each test sample is completed within 1 minute. Less dosage, no pollution. |
test medium | Compressed air or other inert gas |
Sample dosage | About 2g-10g each time, depending on the characteristics of the sample |
OTHER PARAMETERS | |
Signal light source | Imported semiconductor laser, power 30mw, lifespan is more than 70000 hours |
Optical system | Inverse Fourier Combined Optical System |
detector | 128-level multi-element detector, complete forward, backward, lateral omnidirectional information fast feedback, high resolution. |
Instrument size (cm) | Main engine length 79×width 37×height 51 Auxiliary machine length 66×width 32×height 91 |
Instrument weight | about 135kg |
Working power | AC220V ±22V 50Hz ±0.5Hz Environment Temperature: 5℃~35℃; Humidity: <85%; |
Standard analyzer configuration
Item name | Unit | Qty | Remark | |
1 | PA-6000LDWA laser particle size analyzer host | PC | 1 | Including ultrasound, blender, circulation and so on |
2 | PA-6000LDWA particle size analyzer auxiliary | PC | 1 | Including dust, dust storage tank, air purification tank |
3 | Oil-free mute air compressor | PC | 1 |
|
4 | Special granularity analysis software | SET | 1 |
|
5 | Instrument operating instructions | PC | 1 |
|
6 | Factory inspection report, test certificate | PC | Each 1 |
|
7 | power cable | PC | 2 |
|
8 | Serial line, control dedicated line | PC | Each 1 |
|
9 | Sample tank | PC | 2 |
|
10 | Air compressor intake pipe, dust pipe | PC | Each 1 |
|
11 | Screwdriver, brush | PC | Each 1 |
|
12 | Silicone tube | PC | 3 | Backup |
13 | Pulley rubber ring | PC | 10 | Backup |
14 | Inlet valve | SET | 1 |
|
15 | Intake pipes, drains | PC | Each 1 |
|
16 | Sealing pads | PC | 1 | Backup |
17 | Dispersant | Bottle | 1 |
|
18 | standard sample | Batch | 1 |
|
19 | Dustproof glass | PC | 1 |
|
20 | Fuse | PC | 1 |
|
21 | Mixing belt | PC | 1 | Backup |
22 | Sampling spoon | PC | 1 |
|
23 | Silk cloth | Bag | 1 |
|
TEST REPORT