Hematology Analyzer

HMA8800

Product info

Features:

  1. 3-part differentiation of WBC, 23 parameters, single channel counter, up to 35 samples test per hour
  2. Volume measurement by time, not wrong warning
  3. Adanced valve technology,long life
  4. RS232 interface, PC connecting A
  5. Electrical resistance for counting and SFT method of hemoglobin
  6. Low sample consumptio : venous 9.8 ul, capillary 9.8 ul, pre-diluted 20 ul for twice testing one time
  7. 8.4” color TFT, Windows interface all testing parameter displayed simultaneously
  8. Windows operation system graphical buttons mouse and keyboard operation
  9. Double convolution and intelligent fitting
  10. Automatic diluting , Mixing , rinsing and clog clearing
  1. Automatically sample probe cleaning (inside and outside)
  2. Large storage capacity: up to 10,000 samples +3 histograms
  3. RS232 interface, PC connecting

Main Technical Specifications
Methodology: Electrical resistance for counting, hemoglobin cyanide method and SFT method for hemoglobin
Parameter: 3-part differentiation of WBC; 20 parameters and 3 color histograms (WBC, RBC, PLT)
Work mode : Single Channel + unique Hemoglobin test system
Sample volume: 9.6μL for Venous and capillary mode, 20μL for pre-diluted mode
Throughput: More than 35 samples per hour, operate 24 hours a day, auto sleeping and waking-up functions
Storage: up to 100000 sample results including histograms can be stored, convenient for inquiry and management of history data
Operation langue: English
QC control: X-B, L-J, X, SD, CV %
Reference Value Settin: Male, Female, Children, Neonate
Alar: 25 test of alert messages
Input / output: RS232, parallel printer and keyboard
Print: Graphic thermal printer with various printing format, optional external printer
Temperature : 18℃ - 30℃,wet ≤ 10-90%
Power suppl : 220 V ±22 VAC, 50±1Hz
Dimension: 33 CM (L ) * 38 CM ( W ) * 43 CM ( H )
Weight: 20 KG

Precision
Parameters                 linear range            CV %
WBC (10 9 / L)              0.0 - 99.9              ≤2%
RBC (1012 / L)              0.0 - 9.99             ≤1.5%
MCV ( fL )                  40-150                ≤0.5% 
PLT (10 9 / L)              0-999                  ≤4.0%
HGB (g/ )                 0.0-300.0               ≤1.5%
Parameters
WBC, Lymph#, Mid#, Gran#, Lymph%, Mid%, Gran%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV,PDW,PCT,L-PCR
3 –histograms: WBC, RBC and PLT

 

2.HMA8800Vet Hematology analyzer

Features:

  1. Pre progammed for 10 animals plus addition 5 user-defined animals
  2. 3-part differentiation of WBC, 23 parameters, single channel counter up to 35 samples test per hour
  3. Volume measurement by time, not wrong warning
  4. Adanced valve technology,long life
  5. RS232 interface, PC connecting
  6. Electrical resistance for counting and SFT method of hemoglobin
  7. Low sample consumption: venous 9.8 ul, capillary 9.8 ul, pre-diluted 20 ul for twice testing one time
  8. 8.4” color TFT, Windows interface all testing parameter displayed simultaneously
  9. Windows operation system graphical buttons mouse and keyboard operation
  10. Double convolution and intelligent fitting
  11. Automatic diluting, Mixing, rinsing and clog clearing
  12. Automatically sample probe cleaning (inside and outside)
  13. Large storage capacity: up to 10,000 samples +3 histograms
  14. Internal thermal-sensitive printer or external printer.
  15. RS232 interface, PC connecting

Main Technical Specifications

  1. Animal Type: cat, dog, horse, mouse, rat, rabbit, pig, cow, monkey, sheep, plus 5 user-defined animal settings
  2. Methodology: Electrical resistance for counting, hemoglobin cyanide method and SFT method for hemoglobin
  3. Parameter: 3-part differentiation of WBC; 20 parameters and 3 color histograms (WBC, RBC, PLT)
  4. Work mode : Single Channel + unique Hemoglobin test system
  5. Sample volume: 9.6μL for Venous and capillary mode, 20μL for pre-diluted mode
  6. Throughput: More than 35 samples per hour, operate 24 hours a day, auto sleeping and waking-up functions
  7. Storage: up to 100000 sample results including histograms can be stored, convenient for inquiry and management of history data
  8. Operation langue: English
  9. QC control: X-B, L-J, X , SD, CV %
  10. Reference Value Setting: Male, Female, Children, Neonate
  11. Alarm: 25 test of alert messages
  12. Input / output: RS232, parallel printer and keyboard
  13. Prin : Graphic thermal printer with various printing format,  optional external printer
  14. Temperature : 18℃ - 30℃,wet ≤ 10-90%
  15. Power supply: 220 V ±22 VAC, 50±1Hz
  16. Dimension: 33 CM (L) * 38 CM (W) * 43 CM (H)
  17. Weight: 20 KG

Precision
Parameters                 linear range          CV %
WBC (10 9 / L)              0.0 - 99.9             ≤2%
RBC (1012 / L)              0.0 - 9.99             ≤1.5%
MCV (fL)                  40-150               ≤0.5% 
PLT (10 9 / L)              0-999                 ≤4.0%
HGB g/L)                 0.0-300.0              ≤1.5%
Parameters
WBC, Lymph#, Mid#, Gran#, Lymph%, Mid%, Gran%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW, PCT, L-PCR
3 –histograms: WBC, RBC and PLT

8 other products in the same category: