CIT13-10S
CIT13-10S 75 °C thermal stability test instrument used to measure the stability of the substance under high temperature conditions to determine if the substance is too dangerous to transport, suitable for explosive substances, desensitized explosive substances, self-reactive substances and organic peroxides
Availability date:
Product description
CIT13-10S 75 °C thermal stability test instrument used to measure the stability of the substance under high temperature conditions to determine if the substance is too dangerous to transport, suitable for explosive substances, desensitized explosive substances, self-reactive substances and organic peroxides, in line with the United Nations "on the transport of Dangerous Goods Manual of Tests and Criteria recommendations" 13.6.1 test 3 (c): 75 °C thermal stability test.
Instrument consists of two parts, the display control section and the heating system components, the display control section includes a power switch, LCD screen, control buttons and other functional modules, internal heating system design three temperature measurement system, wall unit with a thermocouple.
Product Features
1) Embedded processor, Windows CE operating system;
2) 8-inch LCD touch screen which can display the test status in real time;
3) Digital PID algorithm precise temperature control heating temperature, temperature control accuracy up to ± 1 °C;
4) Built-in hot air circulation heating system, effectively guarantee temperature uniformity and stability;
5) Three-point temperature measurement system, to ensure the accuracy and reliability of test data;
6) Special tube cap relief device, effectively releasing the pressure within the tube;
7) Explosion-proof glass observation window, back pressure relief door design
8) 48 hours unattended test, automatic integration operation
9) real-time display test temperature - time curve, raw data can be searched;
10) Testing process fully automated, without human intervention, support parameter setting, data storage, viewing reports.
Product parameters
1) Operating environment: 5 °C ~ 30 °C, <85% RH
2) Temperature range: room temperature -200 °C
3) Temperature accuracy: ± 1 °C
4) The average temperature of the experimental area:
The following 140 °C of ± 1.5 °C
140 °C ~ 180 °C of ± 2 °C
180 °C ~ 200 °C of ± 2.5 °C
5) Temperature measuring range: 0-500 °C
6) Temperature measurement resolution: 0.1 °C
7) flat-bottomed glass tubes Relief Pressure: ≤60kPa
8) Stopwatch range: 0 to 48 hours
9) Custom time range: 0 to 72 hours