Product info
Control System
- Temperature can be set freely during its range.
- Emerson Dixell brand (imported from Italy) temperature controller.
Alarm System
- Two independent alarm system.
- Compressor fault alarm, compressor high/low voltage alarm, exhaust system high/low temperature alarm, liquid return system alarm, sensor fault alarm, etc.
- The computer connected will display all these working information. History temperature and alarm data can be checked and printed.
Refrigeration Unit
- Kide brand(imported from Spain) High quality full closed/semi-closed compressor, efficiently and low noise
- Efficient air-cooled condenser/water chilling unit, green refrigerant, low noise motor.
- Inner evaporator is equipped with DL ceiling-style or aluminium-alloy-pipe-style air cooler.
- Defrosting automatically
- Two refrigeration units, include a back-up unit.
- Can work under high temperature condition.
Room Body
- Rigid polyurethane heat shield, the outer and inner panel is color plate.
- Eccentric connect type make the room body easy to assemble and connect densely
- Available panel material: color plate, salinization steel, stainless steel, embossing aluminum, etc.
- Room size: customization
- Available room temperature: +15 ~ +8°C, +8 ~ +2°C, +5 ~ -5°C, -15 ~ -25°C, -35 ~ -45°C, -50 ~ -60°C and -70~-80°C (you can choose one temperature range or more than one range at the same time for a freezer room)
Products List
Model | Type | Temperature range | Capacity | Refrigerant | Ambient temp. |
LFZ-CR-DS | Drug storage A | +15 to +8 °C | 10 to 40M3 | R134a | ≤43°C |
LFZ-CR-PR | Drug storage B | +8 to +2 °C | 10 to 40M3 | R134a | ≤43°C |
LFZ-CR-RS | Refrigerating storage | +5 to -5°C | 10 to 40M3 | R134a | ≤43°C |
LFZ-CR-N25 | Freezing storage | -15 to -25°C | 10 to 40M3 | R134a | ≤43°C |
LFZ-CR-N45 | Low temperature storage | -35 to -45°C | 5 to 30M3 | R404a | ≤43°C |
LFZ-CR-N60 | Ultra low storage A | -50 to -60°C | 3 to 15 M3 | R404a & mixture gas | ≤43°C |
LFZ-CR-N80 | Ultra low storage B | -70 to -80°C | 3 to 7 M3 | R404a & mixture gas | ≤43°C |
COOLING SYSTEM
BODY OF COLD ROOM
PACKAGE
INSTALLATION SITE
DOUBLE REFRIGERATION SYSTEM(ONE FOR BACKUP)
If one cooling system failed, the back-up cooling system will start working automatically by double system controller.
If one cooling system under auto-defrosting, the backup cooling system will start to work automatically to keep the inside temperature.
CUSTOMER CASE
Below picture for cold room took in Shenzhen market in 1994
In 2017, this batch of cold room continue working 23 years in the same place, below picture took in 2016.