HRHC-AH Series
Availability date:
Is applied to SUS Reactor, temperature difference >150°C
Rapid cooling at high temperature reaction
Polymerization reaction
Rapid heat-up and cool-down temperature
Dynamic thermostatic control of cold and heat source of high pressure reaction kettle, dynamic thermostatic control of double layer glass reaction kettle, and dynamic thermostatic control of cold and hot source of double-layer reactor.
Microchannel reactor thermostatic control, small temperature control system, steam - feeding system temperature control, material low temperature aging test.
The thermostatic control of the combined chemical cold source heat source, the cooling heating of the semiconductor equipment and the heating temperature of the vacuum chamber are controlled.
Temperature range from 120 to 350, performance superior, unique, high - precision, intelligent temperature control.
High cooling power from 0.5 to 1200kW, highest production stability and repeatable results.
Multi-function alarm system and safety function, use plate heat exchanger, tube type heater to increase heating and cooling rate.
7-inch and 10-inch color TFT touch screen graphics display, use magnetic drive pump, no re-seal leakage problem.
Full airtight system, extended thermal conductivity liquid life, very wide temperature range, no need to change liquid media.
Ultra-high temperature cooling technology can be cooled directly from 300 degrees of high temperature.
The principle and the function has many advantages to using staff: because only expansion of cavity in the body heat conduction medium contact with oxygen in the air (and expansion tank temperature at room temperature to 60 degrees), can achieve lower heat conduction medium absorbed by oxidation and the risk of air moisture.
No heat conduction medium evaporates at high temperature, and it can be achieved -80 ~ 190 degrees, -70 ~ 220 degrees, -88 ~ 170 degrees, -55 ~ 250 degrees, -30 ~ 300 degree continuous temperature control without pressurization.
Adopt full closed pipe design, adopt high efficiency plate heat exchanger, reduce the demand of heat conduction liquid, improve the heat utilization rate of the system, reach the rapid lifting temperature.Thermal conductive medium in a closed system, with a container, expand the heat-conducting medium not participate in circulation in the container, whether high or low temperatures, expansion tank temperature to room temperature to 60 degrees, can reduce the heat conduction medium in running the risk of absorb the moisture and volatile.
Advantage:
Application:
Specifications:
Model | HRHC-AH235W | HRHC-AH255W | HRHC-AH270W | HRHC-AH2A0W | |
Temperature range °C | -25°C~200°C | ||||
Control Mode | Feedback PID + Our special dynamic control calculation, PLC controller | ||||
Temp. control | Material process control | ||||
Program Editor | 20 programs, each program can edit 45 steps | ||||
Communication protocol | MODBUS RTU Protocol,RS485 interface | ||||
Temperature feedback | The temperature of four points: the inlet and outlet of heat-conducting medium, heater and material in reactor(External temperature sensor) | ||||
Refrigeration host | Can set refrigeration host temperature independently | ||||
Temp. accuracy | ±1°C | ±1°C | ±1°C | ±1°C | |
Heating power | 3.5kw | 5.5kw | 7kw | 10kw | |
Cooling capacity | 200°C | 3.5kw | 5.5kw | 7kw | 10kw |
100°C | 3.5kw | 5.5kw | 7kw | 10kw | |
20°C | 3.5kw | 5.5kw | 7kw | 10kw | |
-5°C | 3kw | 4.5kw | 6.6kw | 8kw | |
-20°C | 1.8kw | 2.8kw | 3.8kw | 4.6kw | |
Circulation pump | Max 35L/min 2bar | Max 50L/min 2bar | Max 75L/min 2bar | Max 110L/min 2bar | |
Compressor | Copeland | Copeland | Copeland | Copeland | |
Expansion valve | Danfoss | Danfoss | Danfoss | Danfoss | |
Evaporator | KAORI Plate heat exchanger | ||||
Operation Panel | 7-inch color touch screen controller, temperature curve record, data export to Excel format | ||||
Safety protection | Self-diagnosis function; freezer overload protection; high pressure switch, overload relay, thermal protection device, liquid low level protection, high temperature protection and temperature fault protection. | ||||
Closed circulation system | The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supply oil automatically at low temperature. | ||||
Refrigarant | R-404A | ||||
Connection size | DN20 | DN20 | DN25 | DN32 | |
Water-cooled type W(cooling water at 20°C) | 800L/H 1.5bar~4bar | 1200L/H 1.5bar~4bar | 2000L/H 1.5bar~4bar | 2900L/H 1.5bar~4bar | |
Dimension(mm) | water-cooled | 500*680*1250 | 500*680*1250 | 500*680*1250 | 500*680*1250 |
air-cooled | 500*680*1450 | 500*680*1450 | 500*680*1450 | 650*700*1650 | |
Weight | water-cooled | 160kg | 235kg | 315kg | 390kg |
air-cooled | 195kg | 265kg | 355kg | 425kg | |
Power | AC380V 50HZ 6KW(max) | AC380V 50HZ 8KW(max) | AC380V 50HZ 11KW(max) | AC380V 50HZ 14KW(max) | |
Case material | SUS 304 | SUS 304 | SUS 304 | SUS 304 |