HRHC-2TN Series
Application:
Reactor Systems Autoclaves, Pilot Systems, Mini Plant Systems, Scale up for Operational Development, Double wall reactors, Advanced-Flow Reactors, Distillation Systems, Material Testing, Combinational Chemistry, Semi conductor Industry, Vacuum Chambers.
Availability date:
Advantages & Functions
Structure design
A fully closed piping design, high efficiency plate heat exchanger used to reduce the demand for the thermal fluid utilization while providing the system to achieve the rapid ups and downs in temperature The whole system is a closed liquid circulation system with a expansion of container, expansion of the container and the liquid circulation is adiabatic, it will not in liquid circulation, only mechanical connection, regardless of the temperature is a high temperature or low temperature, the tank temperature is limited to 60°C. The advantages by this design:
Display function
Principle of process control
Change the control settings of the method, the response as soon as possible in the process of the system lags behind, be the smallest system overshoot. Controlled by two PID (PID is a variable in each group) control loop structure, known as the two sets of control loops: the main circuit and from the circuit, the main control loop from the loop output as the settings. System with feed forward with PV, the master PID loop operation results of the PV output and feed forward signals as the composite of the settings from the control loop, through such control of the temperature gradient to ensure the accuracy of temperature control system.
Circulation Pump
High temperature resistant low tempera ture magnetic drive pump or a leak-free high and low temperature shield-driven pump, reduce the risk of system leakage. At the same time the system has the advantages of low noise and big traffic flow.
Electronic expansion valve
Wide temperature range of dynamic temperature control system with electronic expansion valve produced by Emerson company, It can monitor and adjust the number of steps (0~750 Steps / minute) into the motor, precise control the liquid volume from the refrigerant , Improve control accuracy.
Configuration software (Optional)
All dynamic temperature control system HRHC-Series can be connected with the computer.
You can install and record the picture of display on the computer via the configuration software.
Safety protection
Many additional features to ensure the safe operation of the system. For the operation to run not normally appear in the alarm in time and displayed on the touch screen. Phase sequence, leakage protection, refrigeration system high and low voltage protection, overload the pump, compressor overload, high and low level, two independent over-temperature protection, water protection, protection of the circulation line shut.
Connecting Pipe
Items | Temp. range | Interface port |
Fluorine rubber hose | -30~200°C | Φ12*16 Φ16*22 Φ20* 26 |
Metal insulation pipe | -60~250°C | DN15 DN20 DN25 M24*1.5 M30*1.5 M38*1.5 |
Date interface & software
Standard configuration:
Optional:
Common Specifications:
-25°C ~ 200°C Standard One operating two systems
Model | HRHC-2A15W-2TN | HRHC-2A25W-2TN | HRHC-2A38W-2TN | HRHC-2A60W-2TN | HRHC-2A95W-2TN | ||||||
Temperature range | -25°C~200°C | -25°C~200°C | -25°C~200°C | -25°C~200°C | -25°C~200°C | ||||||
Control Mode | Feedback PID + Our special dynamic control calculation, PLC controller | ||||||||||
Temp. control | Option: Process temperature control mode | ||||||||||
Program Editor | Set or control the temperature control or jacket oil temperature control | ||||||||||
Communication Protocol | MODBUS RTU Protocol,RS485 interface | ||||||||||
Temp. feedback | The temperature of four points: the inlet and outlet of heat-conducting medium, heater and material in reactor(External temperature sensor) | ||||||||||
Temp. accuracy | ±1°C | ±1°C | ±1°C | ±1°C | ±1°C | ||||||
Heating power | 15kw | 15kw | 25kw | 25kw | 38kw | 38kw | 60kw | 60kw | 95kw | 95kw | |
Cooling capacity | 200°C | 15kw | 15kw | 25kw | 25kw | 38kw | 38kw | 60kw | 60kw | 90kw | 90kw |
100°C | 15kw | 15kw | 25kw | 25kw | 38kw | 38kw | 60kw | 60kw | 90kw | 90kw | |
20°C | 11kw | 11kw | 18kw | 18kw | 26kw | 26kw | 42kw | 42kw | 68kw | 68kw | |
0°C | 7.5kw | 7.5kw | 13kw | 13kw | 18kw | 18kw | 30kw | 30kw | 50kw | 50kw | |
-20°C | 4.5kw | 4.5kw | 7.5kw | 7.5kw | 11kw | 11kw | 18kw | 18kw | 26kw | 26kw | |
Circulation pump | Max110L/min 2.5bar | Max110L/min 2.5bar | Max150L/min 2.5bar | Max250L/min 2.5bar | Max250L/min 1bar | ||||||
Compressor | Copeland | Copeland | Copeland | Dorin semi-hermetic | Dorin semi-hermetic | ||||||
Expansion valve | Copeland | Copeland | Copeland | Copeland | Copeland | ||||||
Oil separator | Copeland | Copeland | Copeland | Copeland | Copeland | ||||||
Evaporator | KAORI plate heat exchanger | ||||||||||
Operation Panel | Optional 10-inch color touch screen controller, temperature curve record, data export to Excel format | ||||||||||
Safety protection | Self-diagnosis function; freezer overload protection; high pressure switch, overload relay, thermal protection device, liquid low level protection, high temperature protection and temperature fault protection. | ||||||||||
Closed circulation system | The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supply oil automatically at low temperature. | ||||||||||
Refrigerant | R-404A | R-404A | R-404A | R-404A | R-404A | ||||||
Connection size | DN25 PN10 | DN32 PN10 | DN40 PN10 | DN50 PN10 | DN50 PN10 | ||||||
Water-cooled type W(cooling water@30°C) | 5.5m3/H 1.5bar~4bar | 9m3/H 1.5bar~4bar | 12m3/H 1.5bar~4bar | 20m3/H 1.5bar~4bar | 30m3/H 1.5bar~4bar | ||||||
Weight | water-cooled | 680kg | 850kg | 1120kg | 1550kg | 1880kg | |||||
Power | AC 380V 50HZ 40kw(Max) | AC 380V 50HZ 65kw(Max) | AC 380V 50HZ 95kw(Max) | AC 380V 50HZ 150kw(Max) | AC 380V 50HZ 230kw(Max) | ||||||
Case material | SUS 304 | SUS 304 | SUS 304 | SUS 304 | SUS 304 | ||||||
Optional | Optional Ethernet interface, configure the computer operating software | ||||||||||
Optional | Optional outside touch screen display controller(separated),the communication line distance is 10 meter. | ||||||||||
Optional | Water condenser use plate heat exxchanger(request for high quality water) | ||||||||||
Optional | Optional explosion-proof touch screen control system(ExdellBT4),the communication line distance is 15 meter. | ||||||||||
Optional Power | 220V 60HZ three-phase , 440V~460V 60HZ three-phase |
Model | HRHC-225W-2TN HRHC-225-2TN | HRHC-235W-2TN HRHC-235-2TN | HRHC-255W-2TN HRHC-255-2TN | HRHC-275W-2TN HRHC-275-2TN | HRHC-2A10W-2TN HRHC-2A10-2TN | ||||||
Temperature range | -30°C~180°C | -25°C~200°C | -25°C~200°C | -25°C~200°C | -25°C~200°C | ||||||
Control Mode | Feedback PID + Our special dynamic control calculation, PLC controller | ||||||||||
Program Editor | Set or control the temperature control or jacket oil temperature control | ||||||||||
Communication Protocol | MODBUS RTU Protocol,RS485 interface | ||||||||||
Temp. feedback | The temperature of four points: the inlet and outlet of heat-conducting medium, heater and material in reactor(External temperature sensor) | ||||||||||
Temp. accuracy | ±1°C | ±1°C | ±1°C | ±1°C | ±1°C | ||||||
Heating power | 2.5kw | 2.5kw | 3.5kw | 3.5kw | 5.5kw | 5.5kw | 7.5kw | 7.5kw | 10kw | 10kw | |
Cooling capacity | 200°C | 2.5kw | 2.5kw | 3.5kw | 3.5kw | 5.5kw | 5.5kw | 7kw | 7kw | 10kw | 10kw |
100°C | 2.5kw | 2.5kw | 3.5kw | 3.5kw | 5.5kw | 5.5kw | 7kw | 7kw | 10kw | 10kw | |
20°C | 2kw | 2kw | 3kw | 3kw | 5kw | 5kw | 6kw | 6kw | 8.5kw | 8.5kw | |
0°C | 1.5kw | 1.5kw | 2.5kw | 2.5kw | 3kw | 3kw | 5kw | 5kw | 7kw | 7kw | |
-20°C | 1kw | 1kw | 1.6kw | 1.6kw | 2kw | 2kw | 3kw | 3kw | 3.6kw | 3.6kw | |
Circulation pump | Max15L/min 1bar | Max35L/min 2.5bar | Max35L/min 2.5bar | Max50L/min 2.5bar | Max50L/min 2.5bar | ||||||
Compressor | Mitsubishi | Copeland | Copeland | Copeland | Copeland | ||||||
Expansion valve | Danfoss | Danfoss | Danfoss | Danfoss | Danfoss | ||||||
Oil separator | LENYA | LENYA | LENYA | LENYA | LENYA | ||||||
Evaporator | KAORI plate heat exchanger | ||||||||||
Operation Panel | Optional 7-inch color touch screen controller, temperature curve record, data export to Excel format | ||||||||||
Safety protection | Self-diagnosis function; freezer overload protection; high pressure switch, overload relay, thermal protection device, liquid low level protection, high temperature protection and temperature fault protection. | ||||||||||
Closed circulation system | The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supply oil automatically at low temperature. | ||||||||||
Refrigerant | R-404A | ||||||||||
Connection size | DN15 Or M24*1.5 | DN20 Or M30*1.5 | DN20 Or M30*1.5 | DN25 Or M38*1.5 | DN25 Or M38*1.5 | ||||||
Water-cooled type W(cooling water@30°C) | 1000L/H 1.5bar~4bar | 1200L/H 1.5bar~4bar | 1400L/H 1.5bar~4bar | 1700L/H 1.5bar~4bar | 2100L/H 1.5bar~4bar | ||||||
Weight | water-cooled | 180kg | 245kg | 300kg | 350kg | 400kg | |||||
air-cooled | 205kg | 280kg | 340kg | 385kg | 445kg | ||||||
Power | AC 220V 50HZ 6.2kw(Max) | AC 380V 50HZ 10.5kw(Max) | AC 380V 50HZ 15kw(Max) | AC 380V 50HZ 21kw(Max) | AC 380V 50HZ 28.5kw(Max) | ||||||
Case material | SUS 304 | SUS 304 | SUS 304 | SUS 304 | SUS 304 | ||||||
Optional | Optional Ethernet interface, configure the computer operating software | ||||||||||
Optional | Optional outside touch screen display controller(separated),the communication line distance is 10 meter. | ||||||||||
Optional | Water condenser use plate heat exxchanger(request for high quality water) | ||||||||||
Optional | Optional explosion-proof touch screen control system(ExdellBT4),the communication line distance is 15 meter. | ||||||||||
Optional Power | 220V 60HZ three-phase , 440V~460V 60HZ three-phase |