-70°C~250°C Laboratory Hermetic Refrigerating & Heating Circulator (Dynamic Temperature Control systems)

HRHC Series

Application:
Reactor Systems Autoclaves, Pilot Systems, Mini Plant Systems, Scale up for Operational Development, Double wall reactors, Advanced-Flow Reactors, Distillation Systems, Material Testing, Combinational Chemistry, Semi conductor Industry, Vacuum Chambers.

More details

Product info

https://youtu.be/Tfn6DHmV9yY

Advantages & Functions

  • Hermetic circulation system make sure high accuracy of temperature and extend life time of circulating liquid.
  • Widely working temperatures range from -100°C to +350°Cwithout cooling fluid change
  • Intelligent PID temperature control
  • High stability and reproducibility of process
  • Adopted plate heat exchanger, heating pipeline to improve rate of heating & cooling
  • Widely cooling power range from 0.5 to 500 kW
  • Brilliant 4 inch, 7 inch, 10 inch TFT touch screen with graphic display can be choose.
  • Comprehensive warning and safety functions
  • Rapid cooling down from high temperature (from 300°C).
  • Control software is available which can communication in 200 meter distance. (Optional)
  • Incredibly compact

Structure design

A fully closed piping design, high efficiency plate heat exchanger used to reduce the demand for the thermal fluid utilization while providing the system to achieve the rapid ups and downs in temperature The whole system is a closed liquid circulation system with a expansion of container, expansion of the container and the liquid circulation is adiabatic, it will not in liquid circulation, only mechanical connection, regardless of the temperature is a high temperature or low temperature, the tank temperature is limited to 60°C. The advantages by this design:

  • Only the heat conduction medium in the expansion container touches the oxygen in the air. (The container temperature is limited to 60°C), therefore, during the process the risk of imbibing and volatilization of the heat conducting medium is reduced.
  • No volatilization of the heat conducting medium at high temperature.
  • No need to change the heat conducting medium. Continuous control the temperature range to -80°C~190°C, -70°C~220°C, -88°C~170°C, -55°C~250°C, -30°C~300°C without rising the pressure.

 

Display function

  • All the kind of process control temperatures.
  • Liquid level of the heat conducting medium in the expansion vessel.
  • Indication working status of refrigeration system.
  • Indication working status of heater.
  • Indication working status of circulation pump.
  • Temperature control mode (materials and heat transfer medium).
  • Temperature upper limit and lower limit can be set.
  • Temperature difference between jacket & reactor material can be set.
  • Alarm when liquid is empty.
  • Refrigeration compressor can be set to operate manually or automatically.
  • Clear temperature curve displayed, it can be zoom and exported to computer.
  • Recipe procedure set display
  • Alarm note display

Principle of process control 

Change the control settings of the method, the response as soon as possible in the process of the system lags behind, be the smallest system overshoot. Controlled by two PID (PID is a variable in each group) control loop structure, known as the two sets of control loops: the main circuit and from the circuit, the main control loop from the loop output as the settings. System with feed forward with PV, the master PID loop operation results of the PV output and feed forward signals  as the composite of the settings from the control loop, through such control of the temperature gradient to ensure the accuracy of temperature control system.

   

Circulation Pump
High temperature resistant low tempera  ture magnetic drive pump or a leak-free high and low temperature shield-driven pump, reduce the risk of system leakage. At the same time the system has the advantages of low noise and big traffic flow.

Electronic expansion valve
Wide temperature range of dynamic temperature control system with electronic expansion valve produced by Emerson company, It can monitor and adjust the number of steps (0~750 Steps / minute) into the motor, precise control the liquid volume from the refrigerant , Improve control accuracy.

Configuration software (Optional)

All dynamic temperature control system HRHC-Series can be connected with the computer.
You can install and record the picture of display on the computer via the configuration software.

  • Communication distance less than 200m.
  • Easily temperature setting
  • Real time control screen
  • Curve Records
  • Program selection
  • Alarm screen recording

 

Safety protection
Many additional features to ensure the safe operation of the system. For the operation to run not normally appear in the alarm in time and displayed on the touch screen. Phase sequence, leakage protection, refrigeration system high and low voltage protection, overload the pump, compressor overload, high and low level, two independent over-temperature protection, water protection, protection of the circulation line shut.

Connecting Pipe


Items

Temp. range

Interface port

Fluorine rubber hose

-30~200°C

Φ12*16  Φ16*22  Φ20* 26

Metal insulation pipe

-60~250°C

DN15  DN20  DN25  M24*1.5  M30*1.5  M38*1.5

 

Date interface & software
Standard configuration:

  • Inputs of PT100 temperature sensor
  • USB data export interfaces
  • RS485 interface (MODBUS protocol)
  • Alarm contact output

Optional:

  • Inputs of 4 ~ 20mA temperature measurement
  • Inputs of 4 ~ 20mA temperature setting
  • Ethernet interface
  • RS232 interface (MODBUS protocol)
  • Computer operating software (Must be fitted with Ethernet interface)
  • External control box with touch screen display

Common Specifications:

  • Control mode: Feed forward PID, PLC control
  • Temperature control: Temperature of material and circulation liquid can be controlled and set
  • Program:20 group programs, 45 segments for each group
  • Protocol: MODBUS RTU / RS 485 Interface
  • Temp. sensor: Circulation medium PT100, raw material PT100 (3 measuring points) 4~20mA (Optional)
  • Control panel: 7 inches color touch screen, temperature curve display & record
  • Safety: With self-diagnosis function; freezer overload protection; high-pressure switch, a variety of security features overload relays, thermal protection devices.
  • Closed loop system: Fully closed system, no oil mist at high temperature, low temperature do not absorb moisture in the air, the system does not increase the pressure because the high temperature, low temperature heat transfer medium in automatic replenishment operation.

 -70°C~250°C Laboratory


Model

HRHC-725WN

HRHC-735WN
HRHC-735N

HRHC-755W
HRHC-755

HRHC-775W
HRHC-775

HRHC-7A10W

HRHC-7A15W

Temperature range °C

-70°C~250°C

-70°C~250°C

-70°C~250°C

-70°C~250°C

-70°C~250°C

-70°C~250°C

Temp. accuracy

±1°C

±1°C

±1°C

±1°C

±1°C

±1°C

Heating power

2500W

3500W

5500W

7500W

10000W

15000W

Cooling
capacity

250°C

2500W

3500W

5500W

7500W

10000W

15000W

100°C

2500W

3500W

5500W

7500W

10000W

15000W

20°C

2500W

3500W

5500W

7500W

10000W

15000W

0°C

2500W

3500W

5500W

7500W

10000W

15000W

-20°C

2000W

3000W

4850W

6000W

8200W

14000W

-40°C

1300W

1750W

2300W

3100W

4000W

8750W

-60°C

400W

550W

750W

900W

1200W

2800W

Circulation pump

Max20L/min
2BAR

Max35L/min
2BAR

Max35L/min
2BAR

Max50L/min
2.5BAR

Max50L/min
2.5BAR

Max110L/min
2.5BAR

Compressor

Copeland

Copeland

Copeland

Copeland

Copeland

Copeland

Expansion valve

Danfoss

Danfoss

Danfoss

Danfoss

Danfoss

Danfoss

Oil separator

Emerson

Emerson

Emerson

Emerson

Emerson

Emerson

Evaporator

KAORI Plate heat exchanger

KAORI Plate heat exchanger

Refrigerant

R-404A R23

R-404A  R23

R404A  R23

R404A  R23

R404A R23

R404A  R23

Connection size

DN-15 or
M24*1.5

DN20 or
M30*1.5

DN20 or
M30*1.5

DN20 or
M30*1.5

DN20 or
M30*1.5

DN-25
M38*1.5

Water-cooled type W
(cooling water at 20°C)

900L/H
1.5bar~4bar

1200L/H
1.5bar~4bar

1800L/H
1.5bar~4bar

2300L/H
1.5bar~4bar

3200L/H
1.5bar~4bar

4500L/H
1.5bar~4bar

Dimension

water-cooled

400*600*1350

600*700*1150

600*700*1350

600*700*1350

700*700*1350

700*700*1550

air-cooled

 

550*680*1450

620*680*1450

750*750*1750

 

 

Weight

water-cooled

190kg

235kg

275kg

325kg

370kg

420kg

air-cooled

 

275kg

320kg

370kg

 

 

Power

AC 220V 50HZ
5.2kW (max)

AC 380V 50HZ
8kW (max)

AC 380V 50HZ
11kW (max)

AC 380V 50HZ
15kW (max)

AC 380V 50HZ
20kW (max)

AC 380V 50HZ
28kW (max)

Case material

SUS 304

SUS 304

SUS 304

SUS 304

SUS304

SUS304

26 other products in the same category: