Automatic Oxygen Bomb Calorimeter

CBC-600

The CBC-600 automatic calorimeter has the characteristics of high degree of automation, simple structure and exquisite appearance. 

More details

Product info

Application field

The CBC-600 automatic calorimeter has the characteristics of high degree of automation, simple structure and exquisite appearance. The calorimeter contains an internal cylinder water automatic charging and discharging system, and adopts an advanced internal cylinder water measurement method without adding electrolyte to distilled water; the circulating water volume of the system is up to 40 liters, ensuring continuous measurement of more than 20 samples. The system temperature is stable; using CBC-700-11 molding die, the appearance is comparable to similar international products such as IKA and Parr.

 

This product can be used in electric power, coal, metallurgy, petrochemical, environmental protection, building materials, papermaking, geological prospecting, scientific research institutions and other industries to measure the calorific value of combustibles such as coal, coke, petroleum and cement black raw materials. It is especially suitable for coal mines and power plants. , New dry process cement plants and other units conduct conventional coal calorific value detection.

 


Technical characteristics

1. Long-term stability technology of heat capacity

2. Automatic filling and drainage technology

3. No water temperature adjustment technology

4. Low calorific value accurate measurement technology

5. Rapid determination technology

6. Cotton thread ignition technology

7. Accurate prediction technology of H content

8. Fast ash determination technology

 

Technical parameter

Model

CBC-600

Heat capacity precision

≤0.15%

Long-term stability

≤0.20%

Maximum absolute error of calorific value

For coal ≤120KJ/kg, for coal gangue ≤60 KJ/kg

Heat test time

The main period of routine measurement is 8 minutes (12-19 minutes in the whole process), and the main period of coal rapid measurement is 4 minutes (7 minutes in the whole process)

Temperature resolution

0.0001

Test Range

0-32MJ/KG

Environmental requirements

Temperature 2-39, relative humidity<80%

Power requirements

220V±20V, 50Hz±1Hz

Instrument power consumption

<80W

Ash content rapid determination program (Optional)

The ash test time is 5 minutes, the absolute error of the ash parallel sample is ≤0.5%

Host size (length × width × height) (mm)

450×500×390

8 other products in the same category: