Biological Safety Cabinet

BSC Series

Biological safety cabinet is indispensable equipment for modern microorganism lab, especially for those occasions that the operators need to take protective measure, such as medicine, pharmacy, microbiology, biomedicine, gene recombination, animal experiment and biological products. It can provide a sterile clean and safe environment.

More details

Product info

Application Range:
Biological safety cabinet is indispensable equipment for modern microorganism lab, especially for those occasions that the operators need to take protective measure, such as medicine, pharmacy, microbiology, biomedicine, gene recombination, animal experiment and biological products. It can provide a sterile clean and safe environment.

Structural Characteristics:

  1. BSC-IIA2 constant air emissions by 30%, BSC-IIB2 constant air emissions by 100%, negative pressure vertical laminar flow.
  2. Moving up / down glass door, flexible positioned, and can completely shut down for sterilization, alarm prompt.
  3. High efficiency filters to filter particles, dust and microorganism in the air,two layers of filter for more than 99.9999% of the HEPA filter membrane
  4. Using high quality 304 stainless steel,can prevent the corrosion and erosion of disinfectants.
  5. Equipped with an alert function for high efficiency filter failure
  6. The alarm for air leakage in workspace.

Technical Parameters:


Model

BSC-1000IIA2
BSC-1000IIB2

BSC-1300IIA2
BSC-1300IIB2

BSC-1600IIA2
BSC-1600IIB2

Exhaust capacity

30%
100%

30%
100%

30%
100%

Clean level

ISO 5(Class 100)/ISO 4(Class 10)

HEPA Filter Efficiency

@0.3~0.12µm≥99.999% ~ 99.995%

Downflow Air Velocity

0.25m/s~0.5m/s

Inflow Air Velocity

≥0.5m/s

Noise

≤60dB(A)

Vibration Half Peak

≤5µm

Electric Power

AC, Single-phase 220V/50Hz(AC,220V,1¢,50Hz)

Laminar Flow Protection

Operator Protection(Repeat 3 times)

a.Total colony in impaction sampler≤10CFU/time
b.Total colony in crack sampler≤5CFU/time

Sample Protection(Repeat 3 times)

Total colony in culture dish≤5CFU/time

Protection Against Cross-Contamination(Repeat 3 times)

Total colony in culture dish≤2CFU/time

Maximum Power

≤1500KVA(with spare socket)

Weight(kg)

150

200

250

Operation Room Dimension(mm)

1000×570×635

1300×570×635

1600×570×635

Overall Dimension(mm)

1200×855×2350

1500×855×2350

1800×795×2350

Fluorescent Lighting

30W×(2)

40W×(2)

40W×(2)

UV Lighting

20W×(1)

30W×(1)

40W×(1)

Luminance

≥650Lx

Exhaust Pipe’s Diameter

Φ200

Φ250

Exhaust Direction

Top ejection