Auto Biochemical Analyzer

BCA-9050

Product info

 90 pcs reagent cold storage positions, double disk design, 115 sample positons
Reagent 24 hours refrigeration function, to ensure the quality of reagents
Sample pre-dilution, automatic re-check function
Automatic eight-step cleaning, more thorough, more clean
Special cleaning solution, heated distilled water thoroughly washed Cuvette
Cuvette automatic cleaning and cup blank monitoring
Imported long life precision ceramic piston pump, wear, maintenance costs low
To achieve the reagent, the sample of the micro-, save cost
Cleaning fluid and distilled water low liquid level, waste tank high level alarm function
Windows operating interface
Randomly presented supporting Chinese data processing software
Powerful network support function.
Original high-quality liquid stabilization reagent, perfect traceability system

Technical Parameters
Machine performance
Instrument type: random optional discrete type
Test Methods:
     ◆ end-point method, fixed-time method (two-point method), dynamic method (rate method), immune turbidimetry
     ◆ single wavelength / dual wavelength / multi-wavelength method
     ◆ linear and non-linear calibration
     ◆ single / double reagent, single / dual wavelength detection
Test settings: single measurement, multiple determination, combination of project determination, batch determination
Test items: conventional biochemical, specific protein, electrolytes, therapeutic drugs, drug abuse, urine / cerebrospinal fluid, etc.
Project settings: fully open editing test items, free editing project portfolio and calculation items, to avoid mutual interference projects
 
Sample system
Sample plate: a total of 115 sample positions, the whole disk can be replaced, any position can be used for emergency position, in the regular inspection can be inserted emergency samples at any time
Sample tube specifications: micro sample cup, vacuum blood collection tube, plastic tube
Sample size: 1.5 μl to 35 μl, 0.1 μl increment
Sample needle: multi-function integrated sampling needle, with automatic liquid level detection and collision safety protection, automatic internal and external wall cleaning function
Sample needle cleaning: automatic warm water inside and outside the wall full cleaning
Sample processing: automatic dilution, automatic retesting
Accelerator: US imports of syringes, long life high-precision ceramic piston, high precision, wear, low maintenance costs
Other optional features: Barcode scanning

Reagent system
Reagent plate: 90 reagent positions, single, double reagent optional, reagent position can be set arbitrarily, can replace the whole disk
Reagent refrigeration: with 24 hours 4 ~ 12 ℃ reagent continuous refrigeration function, Peltier refrigeration, independent refrigerated power
Reagent bottle: 20ml, 35ml, 70ml, slope bottom design
Test dose: 150μl ~ 300μl, 1μl increments, the test can automatically deduct reagent blank
Reagent needle: multi-functional integration reagent needle, with automatic liquid level detection and anti-collision safety protection function, automatic internal and external wall cleaning function, with reagent preheating, automatic record reagent allowance, inadequate prompt function
Reagent needle cleaning: automatic warm water inside and outside the wall full cleaning
Sampler: US imports of syringes, long life high-precision ceramic piston, high precision sampling, wear, low maintenance costs
Other optional features: Barcode scanning

Reaction system
Reactor: 120 pcs reaction cups, 6mm optical path, hard plastic Cuvette, UV (UV) penetrability, acid and alkali corrosion proof, semi-permanent use, low consumption, low cost
Reaction mode: post-spectral detection
Total volume of the reaction solution: 150 μl to 300 μl
Reaction time: about 10 minutes
Reaction temperature: 37 ° C, temperature accuracy ± 0.1 ° C
Reaction plate temperature: solid hot, maintenance-free daily
Mixing mechanism: independent mixing needle, immediately mix after adding the reagent
Reaction cups cleaning: After measuring the sample, the instrument uses advanced eight-step automatic cleaning, without human intervention. Use the most thorough drain, add the cleaning solution to get rid of the protein, cleaning and drying technology to prevent the occurrence of cross-contamination
Reaction cups cleaning solution: with cleaning fluid and distilled water low level alarm function
Waste treatment: with tank high liquid level alarm function

Optical system
Light source: halogen lamp, 6V / 10W, life ≥ 3000 hours
Grating after splitting, 12 wavelengths of 340nm-800nm
Wavelength Accuracy: ± 2nm
Detector: Photodiode array
Absorbance range: 0.000-3.000Abs
Resolution: 0.001Abs
Stray light: ≤ 0.5%

Calibration and quality control
Calibration method : Nine calibration formulas, linear (single point, two-point and multipoint),Logit-Log4P, Logit-Log5P, Spline, Exponential Function, Polynomial, Parabola, Polyline
Calibration cycle: automatic setting or on-demand setting
Quality control rules: Westgard multi-rule quality control, Cumulative sum check accumulation and rules, Twin plot three ways, to support a variety of concentration levels of quality control
Quality control: real-time quality control, day quality control, day to day quality control

Operating System
Computer operating system: windows 2000 or above, all Chinese operating system
Data Processing: Mass Storage Analysis Sample Test Results, Display, Store and Print Reaction Curve, Support LIS System
Report print: edit and print complete Chinese report card, print content format optional, editable, support network report print
System interface: RS-232 standard interface

Working Environment
Power supply: AC220V ± 22V, 50Hz / 60Hz ± 1Hz
Power consumption: ≤ 500VA
Ambient temperature: 15 ℃ ~ 30 ℃
Maximum relative humidity: 85%
Host volume: 1095 (L) x 670 (W) x 1096 (H)
Weight: 120kg

10 other products in the same category: