To create an evaluation of drug failure need long stable temperature, humidity and light environment for pharmaceutical companies for medicines and accelerated testing of new drugs, long-term test, humidity test and glare testing, pharmaceutical companies drug stability test performed best option, it is necessary equipment of pharmaceutical factory to achieve GMP certification.
Features:
- New CFC-FREE design
- Special sterilization stainless steel, semi-circular arc corners design, easy to clean & operate.
- Microcomputer servo controller, digital temperature and humidity display (MSC-TH/THL series).
- LCD touch screen controller, all functions displayed on the screen in the form of graphics and text, graphs can observe the machine running (MSC-TH/THL series).
- Continuous operation: two imported closed compressor automatically switches to ensure continuous operation of the device.
- Continuous operation without frost
- Adopt imported humidity sensor, to avoid the frequent replacement of annoyance.
- With stepless illumination adjustment function (THL series).
- Programmable touch screen controller
Safety features:
- Breeze circulation and heating will automatically stops when the door is open.
- Circulation fan speed can be controlled automatically.
- Independent limit temperature alarm system that can sound and light alarm operator.
- Temperature deviation alarm, compressor overheating, overload, over voltage protection and water protection.
- Wired alarm monitoring systems
- Compressor overheating protection, fans thermal protection, over-temperature protection, compressor overpressure protection, overload protection, water protection, wired surveillance alarm system
Specifications:
Model |
MSC-TH200D |
MSC-TH300D |
MSC-THL200D |
MSC-THL300D |
MSC-THL425T |
||||||
Temp. range |
0~65°C |
With illumination:10~50°C |
With illumination:10~50°C |
||||||||
Temp. fluctuation |
±0.4°C |
±0.4°C |
±0.4°C |
||||||||
Temp. uniformity |
±2°C |
±2°C |
±2°C |
||||||||
Humidity range |
40~95%RH |
40~95%RH |
40~95%RH |
||||||||
Humidity accuracy |
±3%RH |
±3%RH |
±3%RH |
||||||||
Illumination range/accuracy |
– |
0~6000LX adjustable |
0~6000LX adjustable |
||||||||
Refrigeration |
Imported |
Imported |
Imported |
||||||||
Controller |
Programmable touch LCD |
Programmable touch LCD |
Programmable touch LCD |
||||||||
Sensor |
Pt100 |
Pt100 |
Pt100 |
||||||||
Capacity(L) |
Upper |
Down |
Upper |
Down |
Upper |
Down |
Upper |
Down |
1 |
2 |
3 |
100L |
100L |
150L |
150L |
100L |
100L |
150L |
150L |
100L |
100L |
225L |
|
Inner size(mm) |
500×450×450 |
660×520×450 |
500×450×450 |
660×520×450 |
500×450×450 |
500×450×1000 |
|||||
Illumination |
– |
– |
– |
– |
√ |
– |
√ |
– |
√ |
– |
– |
Shelf |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
4 |