Heating Circulator

HRC Series

Product info

Features

  • Heating Circulator HRC series with function from high temperature to cooling process, from 300°C~50°C.
  • Equipped with heating cooling container, with large heat transfer area, fast heat-up and cool-down, small heat transfer oil demand.
  • Can heat-up and cool-down continuously.
  • The whole cycle is full closed, there is no oil mist at high temperature, heat transfer oil cannot be oxidized and browning.
  • With function of internal PT100 for correcting internal circulation.
  • The whole system is closed with expansion tank, the expansion tank and liquid circulation are thermal insulation, do not participate in liquid circulation, regardless of high or low temperature, the medium in expansion tank is limited to 60°C.

Advantage

  • Small space required
  • Low filling Volume
  • High Pump Capacity
  • Rapid & efficient filling of the complete
  • application with venting
  • +60 °C max. expansion tank temperature
  • Simple operation
  • High level of safety through constant
  • monitoring

Technical Parameters:


Model

HRC-1820
HRC-1820LY

HRC-5020
HRC-5020LY

HRC-A020
HRC-A020LY

HRC-3030

HRC-5030

HRC-A030

Temperature range °C

50°C~170°C

50°C~200°C

50°C~200°C

50°C~300°C

50°C~300°C

50°C~300°C

Controller

PID adaptive controller

Temp. Control optional

Heat-conducting medium outlet temp. control

Communication protocol

MODBUS RTU Protocol, RS 485 Interface

Temperature feedback

Heat-conducting medium temperature feedback PT100

Temp. accuracy

±0.5°C

±0.5°C

±0.5°C

±0.5°C

±0.5°C

±0.5°C

Heating power

2kW

5.5kW

10kW

3kW

5.5kW

10kW

Cooling
capacity

300°C

 

 

 

3kW

5.5kW

10kW

200°C

2kW at 170°C

5.5kW

10kW

2.5kW

5kW

9kW

100°C

1.3kW

4kW

8kW

1.3kW

4kW

7kW

65°C

0.6kW

1.8kW

3.4kW

0.6kW

1.8kW

3kW

 

There is a heat exchanger in the system, it needs to cool by filling water, open the water valve automatically as request.

Circulation pump

Max10L/min
0.7BAR

Max35L/min
2BAR

Max50L/min
2BAR

Max15L/min
2BAR

Max35L/min
2BAR

Max50L/min
2BAR

Heater

Orient electric heater

Independent Temperature limiter

LABFREEZ

Cooler

KAORI Plate heat exchanger

Operation  panel

Display setting temperature and testing temperature; Touch screen display

Safety protection

Self-diagnosis function; freezer overload protection; high pressure switch, overload relay, thermal protection device,
liquid low level protection, high temperature protection and temperature fault protection.

Closed
circulation system

The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature,pressure do not rise up when system is running. The system will supplement oil automatically at low temperature.

Connection size

DN15

DN20

DN-20

DN-20 PN-10 Connection flange

Dimension

320*420*500

500*550*800

500*550*800

500*550*800

600*600*1250

600*600*1250

Weight

35kg

78kg

88kg

85kg

95kg

105kg

Power

AC 220V 50HZ
2.2kW (max)

AC 380V 50HZ
5.9kW (max)

AC 380V 50HZ
10.8kW (max)

AC 380V 50HZ
3.2kW (max)

AC 380V 50HZ
5.9kW (max)

AC 380V 50HZ
10.8kW (max)

Case material

Cold rolled steel

Optional

Optional 7-inch color touch screen controller, temperature curve record, data export to excel format.

Optional

SUS304 case material

Optional power

220V 60HZ three-phase, 440V~480V 60HZ three-phase

Model “LY” means no water -cooling

Model

HRC-A1520

HRC-A2520

HRC-A3820

HRC-A6020

HRC-A9520

HRC-A13020

HRC-A20020

Temperature range °C

50°C~200°C

Controller

PID adaptive controller

Temp. Control optional

Heat-conducting medium outlet temp. control

Communication protocol

MODBUS RTU Protocol, RS 485 Interface

Temperature feedback

Heat-conducting medium temperature feedback PT100

Temp. accuracy

±0.5°C

±0.5°C

±1°C

±1°C

±1°C

±1°C

±2°C

Heating power

15kW

25kW

38kW

60kW
Divide to two
groups heating

95kW
Divide to three
groups heating

130kW
Divide to three
groups heating

200kW
Divide to four
groups heating

Heater can be divided into groups. When the testing temperature reached to (setting temperature -5°C),
it can close the most of heating duty and leave the next group to be PID fuzzy control.

Cooling
capacity

300°C

 

 

 

 

 

 

 

200°C

15kW

25kW

38kW

60kW

95kW

130kW

200kW

100°C

12kW

20kW

30kW

48kW

76kW

100kW

160kW

65°C

5kW

8.5kW

12kW

19kW

30kW

40kW

64kW

 

There is a heat exchanger in the system and it needs water to cool.
Open the water valve automatically according to demand.

Circulation pump

Max50L/min
2.5BAR

Max110L/min
2.5BAR

Max110L/min
2.5BAR

Max250L/min
2.5BAR

Max250L/min
2.5BAR

Max400L/min
2.5BAR

Max400L/min
2.5BAR

Expansion tank volume

35L

65L

90L

160L

240L

300L

500L

Heater

Orient electric heater

Independent temperature limiter

LABFREEZ

Cooler

Plate heat exchanger

Operation panel

Display setting temperature and testing temperature; Touch key display

Safety protection

Self-diagnosis function; freezer overload protection; high pressure switch, overload
relay, thermal protection device, liquid low level protection, high temperature
protection and temperature fault protection.

Closed circulation system

The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature,
pressure do not rise up when system is running. The system will supplement oil automatically at low temperature.

Connection size

DN-25

DN25

DN25

DN40

DN40

DN-50

DN-50

Dimension

600*600*1250

600*600*1250

1200*750*1100

1200*750*1100

1400*750*1300

1400*750*1300

1500*850*1450

Weight

100kg

130kg

170kg

285kg

318kg

450kg

685kg

Power

AC380V 50HZ
15.7kW (max)

AC380V 50HZ
26.5kW (max)

AC380V 50HZ
39.5k (max)

AC380V 50HZ
63kW (max)

AC380V 50HZ
98kW (max)

AC380V 50HZ
135.5kW (max)

AC380V 50HZ
206kW (max)

Case material

Cold rolled steel painting

Optional

Optional 7-inch color touch screen controller, temperature curve record, data export to excel format.

Optional

SUS 304    SUS 304 case material

Optional power

220V 60HZ three-phase, 440V ~ 480V 60HZ three-phase

Model

HRC-A1530

HRC-A2530

HRC-A3830

HRC-A6030

Temperature range °C

50°C ~ 300°C

Controller

PID adaptive controller

Temp. Control optional

Heat-conducting medium outlet temp. control

Communication protocol

MODBUS RTU Protocol, RS 485 Interface

Temperature feedback

Heat-conducting medium temperature feedback PT100

Temp. accuracy

±0.5°C

±1°C

±1°C

±1°C

Heating power

15kW

25kW

38kW

60kW
Divide to two groups heating

Heater can be divided into groups. When the testing temperature reached to (setting temperature -5°C),
it can close the most of heating duty and leave the next group to be PID fuzzy control.

Cooling
capacity

300°C

15kW

25kW

38kW

60kW

200°C

13kW

22kW

32kW

50kW

100°C

10kW

17kW

27kW

40kW

65°C

4kW

6kW

11kW

16kW

 

There is a heat exchanger in the system and it needs water to cool.
Open the water valve automatically according to demand.

Circulation pump

Max50L/min
2.5BAR

Max110L/min
2.5BAR

Max110L/min
2.5BAR

Max250L/min
2.5BAR

Expansion tank volume

50L

80L

120L

220L

Heater

Orient electric heater

Independent temperature limiter

LABFREEZ

Cooler

Plate heat exchanger

Operation panel

Display setting temperature and testing temperature; Touch screen display

Safety protection

Self-diagnosis function; freezer overload protection; high pressure switch, overload
relay, thermal protection device, liquid low level protection, high temperature
protection and temperature fault protection.

Closed
circulation system

The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature,
pressure do not rise up when system is running. The system will supplement oil automatically at low temperature.

Connection size

DN-25

DN-25

DN-25

DN-40

Dimension

600*600*1250

600*600*1250

1200*750*1100

1200*750*1100

Weight

115kg

155kg

195kg

320kg

Power

AC380V 50HZ
16kW (max)

AC380V 50HZ
26.5kW (max)

AC380V 50HZ
39.5k (max)

AC380V 50HZ
63kW (max)

Case material

Cold rolled steel painting

Optional

Optional 7-inch color touch screen controller, temperature curve record, data export to excel format.

Optional

SUS 304    SUS 304 case material

Optional power

220V 60HZ three-phase, 440V ~ 480V 60HZ three-phase