LSRB Series
Alternative to dry ice and liquid nitrogen for low temperature reaction, high temperature precision is mainly used for flasks, beakers, test tubes, such as cooling, heating, thermostats, etc. For hospitals, research, university enzymes in the biological aspects of experiments, detection and identification.
Availability date:
Alternative to dry ice and liquid nitrogen for low temperature reaction, high temperature precision is mainly used for flasks, beakers, test tubes, such as cooling, heating, thermostats, etc. For hospitals, research, university enzymes in the biological aspects of experiments, detection and identification.
Characteristics:
Technical Specifications:
Model | LSRB-4002 | LSRB-4010 | LSRB-4005 | LSRB-3010 | LSRB-3050 | LSRB-2005 | |
Temp. Range (°C) | -40 ~ 99 | -40 ~ 99 | -40 ~ 99 | -30 ~ 99 | -30 ~ 99 | -20 ~ 99 | |
Temp. Stability (°C) | ±0.2 | ||||||
Bath Volume (L) | 2 | 10 | 5 | 10 | 50 | 5 | |
Bath Material | SUS304 | SUS304 | SUS304 | SUS304 | SUS304 | SUS304 | |
Bath Opening (mm) | Ф140×100 | Ф210×250 | Ф210×130 | Ф210×250 | Ф400×280 | Ф210×130 | |
Max flask capacity (ml) | 500 | 2000 | 2000 | 2000 | 20000 | 2000 | |
Cooling Power (W) | 10°C | 290~10 | 1880 | 1300 | 1700 | - | 1150 |
0°C | 1580 | 1100 | 1200 | 7500 | 880 | ||
-10°C | 1360 | 950 | 700 | 4600 | 600 | ||
-20°C | 870 | 610 | 370 | 2570 | 320 | ||
| -30°C | 450 | 310 | 150 | 1040 | - | |
| -40°C | 20 | 10 | - | - | - | |
Refrigerant | R404a | R404a | R404a | R22 | R22 | R22 | |
Heating Power (W) | 300 | 1500 | 1500 | 1500 | 4500 | 1500 | |
Flow Rate (L/min) | - | 20 | 20 | 20 | 30 | 20 | |
Lift (m) | - | 5 ~ 7 | 5 ~ 7 | 5 ~ 7 | 10 ~ 12 | 5 ~ 7 | |
Stirring | Magnetic stirrer, 100 ~ 1000rpm | ||||||
Ambient Temp. (°C) | 5 ~ 25 | ||||||
Power Supply (V/Hz) | 1-phase, 220/50 | ||||||
Safety Protection | Delay, leakage, overcurrent , overheating | ||||||
Outer Material | SPCC steel with powder coating | ||||||
Overall Power (W) | 820 | 2400 | 2200 | 2420 | 7635 | 2100 | |
Weight (kg) | 35 | 84 | 56 | 50 | 300 | 41 | |
Dimensions (mm) | 466×406×420 | 580×455×930 | 415×365×740 | 505×365×797 | 1250×670×1051 | 415×365×740 |
Model | LSRB-4020 | LSRB-4030 | LSRB-8002 | LSRB-8005 | LSRB-8020 | LSRB-1005 | LSRB-1010 | |
Temp. Range (°C) | -40 ~ 99 | -40 ~ 99 | -80 ~ RT | -80 ~ 99 | -80 ~ 99 | -100 ~ -60 | -100 ~ -60 | |
Temp. Stability (°C) | ±0.5 | ±0.5 | ±2 | ±0.2 | ±0.2 | ±2 | ±2 | |
Bath Volume (L) | 20 | 30 | 2 | 5 | 20 | 5 | 10 | |
Bath Opening (mm) (D×H) | 280×300 | 320×235 | 140×110 | 210×130 | 280×220 | 210×180 | 210×250 | |
Bath Material | SUS304 | SUS304 | SUS304 | SUS304 | SUS304 | SUS304 | SUS304 | |
Max flask (ml) | 5000 | 10000 | 500 | 2000 | 5000 | 2000 | 2000 | |
Heating Power (W) | 1500 | 3600 | - | 1500 | 2000W | - | - | |
Cooling power (W) | 10°C | 2480 | 4780 | - | - |
| - | - |
0°C | 2180 | 4180 | - | - |
| - | - | |
-10°C | 1820 | 3670 | - | - |
| - | - | |
-20°C | 1200 | 2310 | - | - |
| - | - | |
-30°C | 600 | 1100 | - | - |
| - | - | |
-40°C | 50 | 480 | 60 ~ 200 | 510 |
| - | - | |
-60°C | - | - | 110 | 210 | 110 | 160 | ||
-80°C | - | - | 40 | 80 | 50 | 70 | ||
-100°C | - | - | - | - | - | 20 | 40 | |
Flow Rate (L/min) | 20 | 20 | - | 20 | 20 | - | - | |
Lift (m) | 5 ~ 7 | 5 ~ 7 | - | 5 ~ 7 | 5 ~ 7 | - | - | |
Refrigerant | R404a | R404a | R404a, R23 | R404a | R404a, R23 | Mixed | Mixed | |
Stirring | Magnetic stirrer, 100 ~ 1000rpm | |||||||
Ambient Temp. (°C) | 5 ~ 25 | |||||||
Power Supply (V/Hz) | 220/50 | 380V/50Hz | ||||||
Overall Power (W) | 2700 | 6088 | 1000 | 2700 | 4500 | 800 | 2050 | |
Outer Material | SPCC steel with powder coating | |||||||
Safety Protection | Delay, leakage, overcurrent , overheating | |||||||
Dimensions (mm) | 580×455×990 | 665×545×1010 | 600×400×495 | 520×455×925 | 905×750×926 | 765×605×965 | 900×700×1000 | |
Weight (kg) | 95 | 120 | 68 | 90 | 170 | 125 | 150 |
Model | LSRB-1020 | LSRB-1030 | LSRB-1050 | LSRB-1205 | LSRB-1210 | LSRB-1220 | LSRB-1230 | LSRB-1250 | |
Temp. Range (°C) | -100 ~ -60 | -100 ~ -60 | -100 ~ -60 | -120 ~ -60 | -120 ~ -60 | -120 ~ -60 | -120 ~ -60 | -120 ~ -60 | |
Temp. Stability (°C) | ±2 | ±2 | ±2 | ±2 | ±2 | ±2 | ±2 | ±2 | |
Bath Volume (L) | 20 | 30 | 50 | 5 | 10 | 20 | 30 | 50 | |
Bath Opening | 280×300 | 320×235 | 400×320 | 210×180 | 210×250 | 280×300 | 320×235 | 400×320 | |
Bath Material | SUS304 | SUS304 | SUS304 | SUS304 | SUS304 | SUS304 | SUS304 | SUS304 | |
Max flask (ml) | 5000 | 10000 | 20000 | 2000 | 2000 | 5000 | 10000 | 20000 | |
Heating Power (W) | - | - | - | - | - | - | - | - | |
Cooling power (W) | -60°C | 600 | 620 | 700 | 110 | 160 | 600 | 620 | 700 |
-80°C | 480 | 480 | 580 | 50 | 70 | 480 | 480 | 580 | |
-100°C | 180 | 200 | 420 | 30 | 40 | 180 | 200 | 420 | |
-120°C | - | - | - | 20 | 20 | 40 | 80 | 125 | |
Flow Rate (L/min) | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | |
Lift (m) | 5 ~ 7 | 5 ~ 7 | 5 ~ 7 | 5 ~ 7 | 5 ~ 7 | 5 ~ 7 | 5 ~ 7 | 5 ~ 7 | |
Refrigerant | Mixed | Mixed | Mixed | Mixed | Mixed | Mixed | Mixed | Mixed | |
Stirring | Magnetic stirrer, 100 ~ 1000rpm | ||||||||
Ambient Temp. (°C) | 5 ~ 25 | 5 ~ 25 | 5 ~ 25 | 5 ~ 25 | 5 ~ 25 | 5 ~ 25 | 5 ~ 25 | 5 ~ 25 | |
Power Supply (V/Hz) | 380/50 | 380/50 | 380/50 | 220/50 | 380/50 | 380/50 | 380/50 | 380/50 | |
Overall Power (W) | 3234 | 3234 | 4876 | 820 | 2050 | 3234 | 3334 | 4876 | |
Outer Material | SPCC steel with powder coating | ||||||||
Safety Protection | Delay, leakage, overcurrent , overheating | ||||||||
Dimensions (mm) | 1160×800×1310 | 1160×800×1310 | 1315×800×1310 | 750×605×965 | 900×700×1000 | 1160×800×1310 | 1160×800×1310 | 1315×800×1310 | |
Weight (kg) | 154 | 180 | 265 | 125 | 150 | 190 | 200 | 265 |